Literature DB >> 7963496

Long-term reproducibility of ambulatory blood pressure.

G A Mansoor1, E J McCabe, W B White.   

Abstract

OBJECTIVE: To compare the reproducibility of ambulatory and office blood pressure readings in established hypertensive subjects when studies are repeated at extended time intervals.
SUBJECTS: Twenty-five hypertensive patients (office diastolic blood pressure > or = 90 mmHg) who were off antihypertensive therapy for at least 4 weeks and had repeat office and ambulatory blood pressures at least 3 months apart under similar study conditions.
METHODS: On the same day, patients underwent office blood pressure readings measured by mercury column sphygmomanometry and then by ambulatory blood pressure monitoring. Ambulatory blood pressure monitoring was done for 24 h, and awake and sleep periods were divided according to a diary kept by each patient. A second study was performed in an identical manner at a mean +/- SD interval of 23 +/- 24 months (range 3-80, median 15). The agreement between studies was assessed by correlation coefficients, coefficients of variation and standard deviation of the differences (SDD).
RESULTS: There were no significant differences in office, 24-h, awake and sleep mean blood pressures between the two studies. Mean 24-h systolic and diastolic blood pressures were 16 and 14 mmHg lower, respectively, than office blood pressure values. Correlation coefficients were significantly higher for 24-h ambulatory blood pressure than office blood pressure, whereas the SDD between visits was significantly lower for 24-h ambulatory blood pressure than office blood pressure.
CONCLUSIONS: These data demonstrate that long-term reproducibility of ambulatory blood pressure is superior to that for office measurement. One implication of this finding is that, in long-term clinical pharmacology trials utilizing ambulatory blood pressure, fewer subjects would be required than for studies that used office blood pressure end-points.

Entities:  

Mesh:

Year:  1994        PMID: 7963496

Source DB:  PubMed          Journal:  J Hypertens        ISSN: 0263-6352            Impact factor:   4.844


  18 in total

Review 1.  Chronotherapeutics for cardiovascular disease.

Authors:  Y A Anwar; W B White
Journal:  Drugs       Date:  1998-05       Impact factor: 9.546

2.  Intensified monitoring of circadian blood pressure and heart rate before and after intravitreous injection of bevacizumab: preliminary findings of a pilot study.

Authors:  Focke Ziemssen; Qi Zhu; Swaantje Peters; Salvatore Grisanti; Mohammed El Wardani; Peter Szurman; Karl U Bartz-Schmidt; Tjalf Ziemssen
Journal:  Int Ophthalmol       Date:  2008-04-17       Impact factor: 2.031

Review 3.  Utility of ambulatory blood pressure monitoring in children and adolescents.

Authors:  John W Graves; Mohammed Mahdi Althaf
Journal:  Pediatr Nephrol       Date:  2006-07-06       Impact factor: 3.714

4.  Average daily blood pressure, not office blood pressure, is associated with progression of cerebrovascular disease and cognitive decline in older people.

Authors:  William B White; Leslie Wolfson; Dorothy B Wakefield; Charles B Hall; Patrick Campbell; Nicola Moscufo; Julia Schmidt; Richard F Kaplan; Godfrey Pearlson; Charles R G Guttmann
Journal:  Circulation       Date:  2011-11-22       Impact factor: 29.690

5.  How many self-measured blood pressure readings are needed to estimate hypertensive patients' "true" blood pressure?

Authors:  M P García-Vera; J Sanz
Journal:  J Behav Med       Date:  1999-02

6.  [Accuracy and precision in blood pressure measurement. Comparative study of home self-measurement with measurement in the clinic and out-patient monitoring].

Authors:  J Divisón; A Puras; C Sanchis; L Artigao; J López Abril; E López De Coca; J Massó; B Rodríguez Paños
Journal:  Aten Primaria       Date:  2001-03-31       Impact factor: 1.137

7.  Long-term reproducibility of ambulatory blood pressure is superior to office blood pressure in the very elderly.

Authors:  P Campbell; N Ghuman; D Wakefield; L Wolfson; W B White
Journal:  J Hum Hypertens       Date:  2010-03-04       Impact factor: 3.012

8.  A series of self-measurements by the patient is a reliable alternative to ambulatory blood pressure measurement.

Authors:  M M Brueren; H J Schouten; P W de Leeuw; G A van Montfrans; J W van Ree
Journal:  Br J Gen Pract       Date:  1998-09       Impact factor: 5.386

9.  Risk of cardiovascular events among women with high normal blood pressure or blood pressure progression: prospective cohort study.

Authors:  David Conen; Paul M Ridker; Julie E Buring; Robert J Glynn
Journal:  BMJ       Date:  2007-08-19

10.  Continuous in vivo blood pressure measurements using a fully implantable wireless SAW sensor.

Authors:  Olive H Murphy; Mohammad Reza Bahmanyar; Alessandro Borghi; Christopher N McLeod; Manoraj Navaratnarajah; Magdi H Yacoub; Christofer Toumazou
Journal:  Biomed Microdevices       Date:  2013-10       Impact factor: 2.838

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.