Literature DB >> 2201712

Intravascular ultrasonography versus digital subtraction angiography: a human in vivo comparison of vessel size and morphology.

C J Davidson1, K H Sheikh, J K Harrison, S I Himmelstein, M E Leithe, K B Kisslo, T M Bashore.   

Abstract

The accuracy of catheter-based intravascular ultrasonography to define luminal size in humans in vivo and its sensitivity to describe lesion morphology have not been previously reported. Vessel diameter, cross-sectional area and lesion characteristics assessed by digital subtraction angiography and intravascular ultrasonography (20 MHz) were compared in 86 human arterial segments. The same arterial segments were imaged and analyzed by digital subtraction angiography and intravascular ultrasonography at 49 femoral, 3 renal, 5 iliac, 7 pulmonary and 22 aortic sites. Digital subtraction angiographic diameter and area were determined geometrically by an automated algorithm. Intravascular ultrasonographic diameter and area were determined by planimetry. Linear correlation for diameter by the two techniques was 0.97, standard error of the estimate (SEE) = 1.83 mm, and for cross-sectional area it was 0.95, SEE = 0.65 cm2. Intravascular ultrasonography identified 24 sites in which plaque was present; 11 (46%) of these segments appeared normal by digital subtraction angiography. Conversely, digital subtraction angiography demonstrated irregularities in 18 segments of which 5 (28%) appeared normal by intravascular ultrasonography. These data indicate an excellent correlation between intravascular ultrasonography and digital subtraction angiography for in vivo assessment of human arterial dimensions in normal and minimally diseased segments. However, intravascular ultrasonography is more likely to identify atherosclerotic plaque that may be angiographically "silent."

Entities:  

Mesh:

Year:  1990        PMID: 2201712     DOI: 10.1016/0735-1097(90)90354-r

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  7 in total

1.  Improvement of coronary morphology and blood flow after stenting. Assessment by intravascular ultrasound and intracoronary Doppler.

Authors:  J Ge; R Erbel; J Zamorano; M Haude; P Kearney; G Görge; J Meyer
Journal:  Int J Card Imaging       Date:  1995-06

Review 2.  Intravascular ultrasound imaging of peripheral arteries as an adjunct to balloon angioplasty and atherectomy.

Authors:  Y Korogi; T Hirai; M Takahashi
Journal:  Cardiovasc Intervent Radiol       Date:  1996 Jan-Feb       Impact factor: 2.740

3.  Parameters that influence accuracy and precision of quantitative coronary arteriography.

Authors:  G Finet; J Liénard
Journal:  Int J Card Imaging       Date:  1996-12

4.  Quantitative assessment of peripheral and coronary artery lesions before and after balloon angioplasty: a comparison of intravascular ultrasound and angiography.

Authors:  M Schartl; W Bocksch; T Linderer; S Beckmann; S Dreysse
Journal:  Heart Vessels       Date:  1994       Impact factor: 2.037

5.  Imaging of pulmonary vascular disease by intravascular ultrasound.

Authors:  P J Scott; A R Essop; W al-Ashab; A Deaner; J Parsons; G Williams
Journal:  Int J Card Imaging       Date:  1993-09

6.  Intravascular ultrasound imaging of angiographically normal coronary arteries: a prospective study in vivo.

Authors:  J Ge; R Erbel; T Gerber; G Görge; L Koch; M Haude; J Meyer
Journal:  Br Heart J       Date:  1994-06

7.  Documentation of experimentally induced thrombus formation using intravascular ultrasound.

Authors:  J J Ferguson; J C Ober; S K Edelman; L M Buja; J T Willerson
Journal:  Tex Heart Inst J       Date:  1991
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.