Literature DB >> 7960781

The estimation of occupational effective dose in diagnostic radiology with two dosimeters.

L T Niklason1, M V Marx, H P Chan.   

Abstract

Annual effective dose limits have been proposed by national and international radiation protection committees. Radiation protection agencies must decide upon a method of converting the radiation dose measured from dosimeters to an estimate of effective dose. A proposed method for the estimation of effective dose from the radiation dose to two dosimeters is presented. Correction factors are applied to an over-apron collar dose and an under-apron dose to estimate the effective dose. Correction factors are suggested for two cases, both with and without a thyroid shield. Effective dose may be estimated by the under-apron dose plus 6% of the over-collar dose if a thyroid shield is not worn or plus 2% of the over-collar dose if a thyroid shield is worn. This method provides a reasonable estimate of effective dose that is independent of lead apron thickness and accounts for the use of a thyroid shield.

Mesh:

Year:  1994        PMID: 7960781     DOI: 10.1097/00004032-199412000-00003

Source DB:  PubMed          Journal:  Health Phys        ISSN: 0017-9078            Impact factor:   1.316


  8 in total

Review 1.  Personal dosimetry for interventional operators: when and how should monitoring be done?

Authors:  C J Martin
Journal:  Br J Radiol       Date:  2010-12-15       Impact factor: 3.039

Review 2.  Occupational radiation doses to operators performing fluoroscopically-guided procedures.

Authors:  Kwang Pyo Kim; Donald L Miller; Amy Berrington de Gonzalez; Stephen Balter; Ruth A Kleinerman; Evgenia Ostroumova; Steven L Simon; Martha S Linet
Journal:  Health Phys       Date:  2012-07       Impact factor: 1.316

Review 3.  C-arm fluoroscopy in orthopaedic surgical practice.

Authors:  Ishaq Ojodu; Ayodele Ogunsemoyin; Sascha Hopp; Tim Pohlemann; Oluwole Ige; Oluwaseun Akinola
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-05-23

4.  Radiation doses to operators performing transjugular intrahepatic portosystemic shunt using a flat-panel detector-based system and ultrasound guidance for portal vein targeting.

Authors:  Roberto Miraglia; Roberta Gerasia; Luigi Maruzzelli; Mario D'Amico; Angelo Luca
Journal:  Eur Radiol       Date:  2016-08-25       Impact factor: 5.315

5.  Reduction of radiation doses to patients and staff during endoscopic retrograde cholangiopancreatography.

Authors:  Abdelmoneim Sulieman; Georgios Paroutoglou; Andreas Kapsoritakis; Anargeyros Kapatenakis; Spiros Potamianos; Marianna Vlychou; Kiki Theodorou
Journal:  Saudi J Gastroenterol       Date:  2011 Jan-Feb       Impact factor: 2.485

6.  Radiation hazards to vascular surgeon and scrub nurse in mobile fluoroscopy equipped hybrid vascular room.

Authors:  Jong Bin Kim; Jaehoon Lee; Kihyuk Park
Journal:  Ann Surg Treat Res       Date:  2017-02-24       Impact factor: 1.859

7.  Assessment of occupational radiation dose in interventional settings.

Authors:  Fabiola Cretti
Journal:  Med Lav       Date:  2018-02-01       Impact factor: 1.275

8.  Evaluation of the occupational doses of interventional radiologists.

Authors:  Gerritjan Kuipers; Xandra L Velders; Robbert J de Winter; Jim A Reekers; Jan J Piek
Journal:  Cardiovasc Intervent Radiol       Date:  2008-02-12       Impact factor: 2.740

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.