| Literature DB >> 7960781 |
L T Niklason1, M V Marx, H P Chan.
Abstract
Annual effective dose limits have been proposed by national and international radiation protection committees. Radiation protection agencies must decide upon a method of converting the radiation dose measured from dosimeters to an estimate of effective dose. A proposed method for the estimation of effective dose from the radiation dose to two dosimeters is presented. Correction factors are applied to an over-apron collar dose and an under-apron dose to estimate the effective dose. Correction factors are suggested for two cases, both with and without a thyroid shield. Effective dose may be estimated by the under-apron dose plus 6% of the over-collar dose if a thyroid shield is not worn or plus 2% of the over-collar dose if a thyroid shield is worn. This method provides a reasonable estimate of effective dose that is independent of lead apron thickness and accounts for the use of a thyroid shield.Mesh:
Year: 1994 PMID: 7960781 DOI: 10.1097/00004032-199412000-00003
Source DB: PubMed Journal: Health Phys ISSN: 0017-9078 Impact factor: 1.316