Literature DB >> 7949699

A comparison of the effects of automated percutaneous diskectomy and conventional diskectomy on intradiscal pressure, disk geometry, and stiffness.

M Shea1, T Y Takeuchi, R H Wittenberg, A A White, W C Hayes.   

Abstract

Diskectomy, chemonucleolysis, percutaneous diskectomy, and laser ablation are used to treat patients with sciatica. The effects of percutaneous diskectomy on the intradiscal pressure of the human disk are not known. Our aims were to determine (a) whether removal of nucleus through automated percutaneous diskectomy significantly reduces intradiscal pressure without altering the disk geometry and stiffness, and if so, how much nucleus removal is required to achieve these goals; and (b) whether the effects of conventional diskectomy on these same parameters are equivalent to removal of nucleus through automated percutaneous diskectomy. Cyclic compressive loads of 20-900 N were applied to lumbar disks. Conventional diskectomy or automated percutaneous diskectomy (performed for 40 min with biomechanical measurements made four times at 10-min intervals) was then performed under zero load and the specimens retested under the same cyclic compressive loading. There were significant (p < 0.01) decreases in intradiscal pressure (by 7% under 900 N) after 10 min of automated percutaneous lumbar diskectomy. There were no further significant decreases in pressure during the next 30 min of percutaneous diskectomy. There were also significant decreases in pressure due to a puncture hole made with the Nucleotome trephine alone, without removal of disk material, and there was no difference in pressure after trephining alone and after percutaneous diskectomy. Decreases in disk height were significant, ranging from 5% at 10 min to 7% at 40 min of treatment. There were equivalent decreases in intradiscal pressure and disk height due to removal of similar amounts of nucleus during conventional diskectomy and during 40 min of percutaneous diskectomy.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1994        PMID: 7949699

Source DB:  PubMed          Journal:  J Spinal Disord        ISSN: 0895-0385


  9 in total

1.  Replacing the nucleus pulposus of the intervertebral disk: prediction of suitable properties of a replacement material using finite element analysis.

Authors:  J R Meakin
Journal:  J Mater Sci Mater Med       Date:  2001-03       Impact factor: 3.896

2.  Design Requirements for Annulus Fibrosus Repair: Review of Forces, Displacements, and Material Properties of the Intervertebral Disk and a Summary of Candidate Hydrogels for Repair.

Authors:  Rose G Long; Olivia M Torre; Warren W Hom; Dylan J Assael; James C Iatridis
Journal:  J Biomech Eng       Date:  2016-02       Impact factor: 2.097

3.  Human Disc Nucleotomy Alters Annulus Fibrosus Mechanics at Both Reference and Compressed Loads.

Authors:  Amy A Claeson; Edward J Vresilovic; Brent L Showalter; Alexander C Wright; James C Gee; Neil R Malhotra; Dawn M Elliott
Journal:  J Biomech Eng       Date:  2019-05-29       Impact factor: 2.097

4.  Axial creep loading and unloaded recovery of the human intervertebral disc and the effect of degeneration.

Authors:  Grace D O'Connell; Nathan T Jacobs; Sounok Sen; Edward J Vresilovic; Dawn M Elliott
Journal:  J Mech Behav Biomed Mater       Date:  2011-02-22

Review 5.  Mechanical design criteria for intervertebral disc tissue engineering.

Authors:  Nandan L Nerurkar; Dawn M Elliott; Robert L Mauck
Journal:  J Biomech       Date:  2010-01-18       Impact factor: 2.712

6.  Validation and application of an intervertebral disc finite element model utilizing independently constructed tissue-level constitutive formulations that are nonlinear, anisotropic, and time-dependent.

Authors:  Nathan T Jacobs; Daniel H Cortes; John M Peloquin; Edward J Vresilovic; Dawn M Elliott
Journal:  J Biomech       Date:  2014-06-17       Impact factor: 2.712

7.  Automated percutaneous lumbar discectomy: technique, indications and clinical follow-up in over 1000 patients.

Authors:  G Bonaldi
Journal:  Neuroradiology       Date:  2003-09-13       Impact factor: 2.804

8.  Biomechanical characterization of an annulus-sparing spinal disc prosthesis.

Authors:  Glenn R Buttermann; Brian P Beaubien
Journal:  Spine J       Date:  2009-06-21       Impact factor: 4.166

9.  An injectable nucleus pulposus implant restores compressive range of motion in the ovine disc.

Authors:  Neil R Malhotra; Woojin M Han; Jesse Beckstein; Jordan Cloyd; Weiliam Chen; Dawn M Elliott
Journal:  Spine (Phila Pa 1976)       Date:  2012-08-15       Impact factor: 3.468

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.