Literature DB >> 7949561

Accurate measurement of carotid stenosis. Chaos in methodology.

J F Toole1, J E Castaldo.   

Abstract

The methods used for measurement of carotid artery stenosis are not uniform. Witness the chaos that developed when the North American Symptomatic Carotid Endarterectomy Trial (NASCET) group changed its classification system from area to linear measurements only to discover that the European Carotid Stenosis Trial (ECST) used still another angiographic definition of degree of stenosis so that the data from the two studies were not comparable. Fortunately, this has been reconciled by recalculation of the data. In still other studies, using unvalidated ultrasound instruments has made it difficult or impossible to compare results. In part, these problems have been the result of misdirected attempts to amalgamate concepts from Doppler and duplex ultrasound with those of arteriography. The former is more precise and accurate than the latter, yet its methodology is harder to apply and has not been generally distributed. Even such anatomical terms as "carotid bulb" are not standard. Ultrasonographers consider it to be the distal common carotid artery, to vascular surgeons it is the carotid sinus, while still others consider it to be both or neither. The present authors advocate a uniform methodology utilizing duplex ultrasound and predict that it plus magnetic resonance angiography will become the standard by which extracranial carotid artery disease is evaluated in the future.

Entities:  

Mesh:

Year:  1994        PMID: 7949561     DOI: 10.1111/jon199444222

Source DB:  PubMed          Journal:  J Neuroimaging        ISSN: 1051-2284            Impact factor:   2.486


  5 in total

1.  Three-dimensional color Doppler sonography in carotid artery stenosis.

Authors:  Robert A Bucek; Markus Reiter; Albert Dirisamer; Markus Haumer; Angelika Fritz; Erich Minar; Johannes Lammer
Journal:  AJNR Am J Neuroradiol       Date:  2003-08       Impact factor: 3.825

2.  Surgery for carotid artery stenosis.

Authors:  James F Toole
Journal:  BMJ       Date:  2004-09-18

3.  [Grading of carotid stenoses: NASCET will become the reference parameter of DEGUM criteria].

Authors:  C Arning; G M von Reutern; B Widder; H Stiegler; M Görtler
Journal:  Nervenarzt       Date:  2011-08       Impact factor: 1.214

Review 4.  Ultrasound and angiography in the selection of patients for carotid endarterectomy.

Authors:  Andrei V Alexandrov
Journal:  Curr Cardiol Rep       Date:  2003-03       Impact factor: 2.931

5.  Physiologic blood flow is turbulent.

Authors:  Khalid M Saqr; Simon Tupin; Sherif Rashad; Toshiki Endo; Kuniyasu Niizuma; Teiji Tominaga; Makoto Ohta
Journal:  Sci Rep       Date:  2020-09-23       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.