Literature DB >> 7942172

New radiolucent head fixation made of engineering plastics for intraoperative CT scanning.

H Okudera1, S Kobayashi, K Kyoshima, K Tokushige, K Sugita.   

Abstract

A newly developed head fixation for intraoperative computerized tomographic (IOCT) scanning is presented. The system is developed based on the head holder of multipurpose head frame and is made of two kinds of advanced engineering material; carbon fiber reinforced plastic for head holder and frames, polyamide-imide polymer for joints, screws, and head pin. Clinical tests including autoclaving and sterilization were performed and revealed all materials had sufficient strength for clinical use. This fixation system enables us to increase the efficacy of IOCT scanning during open-field neurosurgery.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7942172     DOI: 10.1007/bf01808559

Source DB:  PubMed          Journal:  Acta Neurochir (Wien)        ISSN: 0001-6268            Impact factor:   2.216


  15 in total

1.  Technical note: mobile CT scanner gantry for use in the operating room.

Authors:  H Okudera; S Kobayashi; K Sugita
Journal:  AJNR Am J Neuroradiol       Date:  1991 Jan-Feb       Impact factor: 3.825

2.  Intraoperative digital subtraction angiography and the surgical treatment of intracranial aneurysms and vascular malformations.

Authors:  N A Martin; J Bentson; F Viñuela; G Hieshima; M Reicher; K Black; J Dion; D Becker
Journal:  J Neurosurg       Date:  1990-10       Impact factor: 5.115

3.  Intra-operative computerized axial tomography.

Authors:  M N Shalit; Y Israeli; S Matz; M L Cohen
Journal:  Surg Neurol       Date:  1979-05

4.  Rigid head fixation for intraoperative computed tomography.

Authors:  D J Engle; L D Lunsford; T Panichelli
Journal:  Neurosurgery       Date:  1986-08       Impact factor: 4.654

5.  Experience with intraoperative CT scanning in brain tumors.

Authors:  M N Shalit; Y Israeli; S Matz; M L Cohen
Journal:  Surg Neurol       Date:  1982-05

6.  Intraoperative imaging with a therapeutic computed tomographic scanner.

Authors:  L D Lunsford; R Parrish; L Albright
Journal:  Neurosurgery       Date:  1984-10       Impact factor: 4.654

7.  An improved neurosurgical system: new operating table, chair, microscope and other instrumentation.

Authors:  S Kobayashi; K Sugita; K Matsuo
Journal:  Neurosurg Rev       Date:  1984       Impact factor: 3.042

8.  Intraoperative angiography in cerebral aneurysm and AV-malformation.

Authors:  B L Bauer
Journal:  Neurosurg Rev       Date:  1984       Impact factor: 3.042

9.  A newly designed multipurpose microneurosurgical head frame. Technical note.

Authors:  K Sugita; T Hirota; T Mizutani; N Mutsuga; M Shibuya; R Tsugane
Journal:  J Neurosurg       Date:  1978-04       Impact factor: 5.115

10.  Intraoperative intracranial angiography.

Authors:  R W Smith
Journal:  Neurosurgery       Date:  1977 Sep-Oct       Impact factor: 4.654

View more
  1 in total

1.  Retrograde suction decompression of a large internal carotid aneurysm using a balloon guide catheter combined with a blood-returning circuit and STA-MCA bypass: a technical note.

Authors:  Fumihiro Matano; Takayuki Mizunari; Shushi Kominami; Masanori Suzuki; Yu Fujiki; Asami Kubota; Shiro Kobayashi; Yasuo Murai; Akio Morita
Journal:  Neurosurg Rev       Date:  2016-12-16       Impact factor: 3.042

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.