Literature DB >> 632895

A newly designed multipurpose microneurosurgical head frame. Technical note.

K Sugita, T Hirota, T Mizutani, N Mutsuga, M Shibuya, R Tsugane.   

Abstract

A new multipurpose head frame has been designed for microneurosurgery. It consists of a head holder with a frame to hold self-retaining brain retractors, hand rests, instrument holders, a plate for cotton patties, and skin-flap retractors. It has been satisfactorily used in 100 operations for 1 year.

Mesh:

Year:  1978        PMID: 632895     DOI: 10.3171/jns.1978.48.4.0656

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  16 in total

1.  Combined pre- and retrosigmoid approach for petroclival meningiomas with the aid of a rotatable head frame: peri-auricular three-quarter twist-rotation approach: technical note.

Authors:  Kazuhiko Fujitsu; Yohichi Kitsuta; Yasunori Takemoto; Shigeo Matsunaga; Kensuke Tateishi
Journal:  Skull Base       Date:  2004-11

2.  Two surgeons four-hand microneurosurgery with universal holder system: technical note.

Authors:  Ali Zomorodi; Takanori Fukushima
Journal:  Neurosurg Rev       Date:  2017-02-28       Impact factor: 3.042

3.  Minimal access to deep intracranial lesions using a serial dilatation technique: case-series and review of brain tubular retractor systems.

Authors:  Saleh A Almenawer; Louis Crevier; Naresh Murty; Amin Kassam; Kesava Reddy
Journal:  Neurosurg Rev       Date:  2012-12-06       Impact factor: 3.042

4.  New radiolucent head fixation made of engineering plastics for intraoperative CT scanning.

Authors:  H Okudera; S Kobayashi; K Kyoshima; K Tokushige; K Sugita
Journal:  Acta Neurochir (Wien)       Date:  1994       Impact factor: 2.216

5.  A newly designed attachment device of multipurpose frame for neuronavigator. Technical note.

Authors:  A K Singh; H Okudera; S Kobayashi; M Osawa; K Tokushige
Journal:  Acta Neurochir (Wien)       Date:  1994       Impact factor: 2.216

6.  An improved neurosurgical system: new operating table, chair, microscope and other instrumentation.

Authors:  S Kobayashi; K Sugita; K Matsuo
Journal:  Neurosurg Rev       Date:  1984       Impact factor: 3.042

7.  Combined retractor and hand-rest system for neurosurgery.

Authors:  J M Gilsbach; T Lutze; W Seeger
Journal:  Neurosurg Rev       Date:  1984       Impact factor: 3.042

8.  A stable positioning for patients requiring large calvarial exposure for surgical correction of cranial synostosis.

Authors:  J Behnke; K Mursch; H G Luhr; E Markakis
Journal:  Acta Neurochir (Wien)       Date:  1996       Impact factor: 2.216

9.  Subdural fluid collections following transcortical approach to intra- or paraventricular tumours.

Authors:  Y Tanaka; K Sugita; S Kobayashi; T Takemae; A S Hegde
Journal:  Acta Neurochir (Wien)       Date:  1989       Impact factor: 2.216

10.  Clinical study of brain retraction in different approaches and diseases.

Authors:  A Yokoh; K Sugita; S Kobayashi
Journal:  Acta Neurochir (Wien)       Date:  1987       Impact factor: 2.216

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.