Literature DB >> 7934540

Safety and tolerability of dobutamine-atropine stress echocardiography: a prospective, multicentre study. Echo Dobutamine International Cooperative Study Group.

E Picano1, W Mathias, A Pingitore, R Bigi, M Previtali.   

Abstract

Diagnostic tests that are hazardous or infeasible, or both, may become accepted before inadequacies are recognised; only multicentre trials can provide the necessary information for an unrestricted acceptance of any new diagnostic procedure. We prospectively studied the results obtained in 24 experienced echocardiography laboratories. 2949 tests were done in 2799 patients. In 341 tests (12% of the overall population, 21% of the negative tests) the test could not be completed because of complex ventricular tachyarrhythmias (134, 38% of all submaximal studies); nausea and/or headache (71, 20%); hypotension and/or bradycardia (62, 17%); supraventricular tachyarrhythmias (44, 12%); hypertension (24, 7%); and others (20, 6%). Dangerous events (life-threatening complications or side-effects requiring specific treatment and lasting more than 3 hours, or new hospital admission) occurred in 14 cases (1 every 210 tests)--9 cardiac (3 ventricular tachycardias; 2 ventricular fibrillations; 2 myocardial infarctions; 1 prolonged antidote-resistant myocardial ischaemia; 1 severe, persistent hypotension) and 5 extracardiac (atropine poisoning with hallucinations lasting several hours in the absence of either myocardial ischaemia or hypotension). Life-threatening and/or longlasting complications may occur during dobutamine/atropine stress echocardiography. The test is generally well tolerated, although may be interrupted by minor, self-limiting, usually symptomless side-effects.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7934540     DOI: 10.1016/s0140-6736(94)90508-8

Source DB:  PubMed          Journal:  Lancet        ISSN: 0140-6736            Impact factor:   79.321


  50 in total

1.  Safety and feasibility of atropine added to submaximal exercise stress testing with Tl-201 SPECT for the diagnosis of myocardial ischemia.

Authors:  Sanjay K Prasad; Dudley J Pennell
Journal:  J Nucl Cardiol       Date:  2002 Nov-Dec       Impact factor: 5.952

2.  Prognostic value of real time dobutamine stress myocardial contrast echocardiography in patients with chest pain syndrome.

Authors:  Geu-Ru Hong; Jong-Seon Park; Sang-Hee Lee; Dong-Gu Shin; Ung Kim; Jung Hyun Choi; Robin Abdelmalik; Jesús A Vera; Jin-Kyung Kim; Jagat Narula; Mani A Vannan
Journal:  Int J Cardiovasc Imaging       Date:  2011-12-06       Impact factor: 2.357

3.  Exercise echocardiography.

Authors:  Jesus Peteiro; Alberto Bouzas-Mosquera
Journal:  World J Cardiol       Date:  2010-08-26

Review 4.  Cardiac imaging in coronary artery disease: differing modalities.

Authors:  J D Schuijf; L J Shaw; W Wijns; H J Lamb; D Poldermans; A de Roos; E E van der Wall; J J Bax
Journal:  Heart       Date:  2005-08       Impact factor: 5.994

5.  Atropine for exercise testing after acute myocardial infarction.

Authors:  Eliana Reyes
Journal:  Int J Cardiovasc Imaging       Date:  2005-08       Impact factor: 2.357

6.  Tolerance, hemodynamic changes, and safety of dobutamine stress perfusion imaging.

Authors:  H A Dakik; H Vempathy; M S Verani
Journal:  J Nucl Cardiol       Date:  1996 Sep-Oct       Impact factor: 5.952

Review 7.  Cardiovascular imaging in cardio-oncology.

Authors:  Amir Abbas Mahabadi; Christoph Rischpler
Journal:  J Thorac Dis       Date:  2018-12       Impact factor: 2.895

8.  Second-opinion stress tele-echocardiography for the Adonhers (Aged donor heart rescue by stress echo) project.

Authors:  Daniele Franchi; Davide Cini; Giorgio Arpesella; Sonia Gherardi; Italo Calamai; Giuseppe Barletta; Serafina Valente; Emilio Pasanisi; Stefania Sansoni; Caterina Ricci; Walter Serra; Eugenio Picano; Tonino Bombardini
Journal:  Cardiovasc Ultrasound       Date:  2010-06-01       Impact factor: 2.062

9.  The risks of inappropriateness in cardiac imaging.

Authors:  Eugenio Picano
Journal:  Int J Environ Res Public Health       Date:  2009-05-14       Impact factor: 3.390

Review 10.  Stress echocardiogaphy: a useful test for assessing cardiac risk in diabetes.

Authors:  Rajan Sharma; Denis Pellerin
Journal:  Vasc Health Risk Manag       Date:  2009-04-08
View more