Literature DB >> 7929465

Predicting the compressive mechanical behavior of bone.

T S Keller1.   

Abstract

The principal objectives of this study were to determine the mathematical dependency of the compressive mechanical properties of human bone on several commonly used measures of bone composition, and to assess variations in this dependency based upon the composition range spanned by the data. Destructive mechanical tests were conducted along the superior-inferior axis of 496 cubic specimens of human trabecular and cortical bone from five male donors (ages 46-84 yr), including specimens from lumbar vertebrae and femoral metaphyses and diaphyses. There was over a 3000-fold variation in strength (S, ultimate stress) and over a 20,000-fold variation in stiffness (E, elastic modulus) over the range of apparent dry density (rho a = 0.05-1.89 g cm-3), apparent ash density (rho alpha = 0.03-1.22 g cm-3) and mineral content (alpha = 17.4-66.2%) examined. Both linear and power models produced very high correlations (R2 > 0.81) between mechanical properties and bone composition, but the linear models resulted in a much greater percent deviation (PD) of the predicted dependent variable with respect to the measured value, in comparison to power models. The best correlations were obtained using rho alpha as the only independent variable: S (MPa) = 117 rho alpha 1.93 +/- 0.04 (R2 = 0.969, PD = 29.9, E (GPa) = 10.5 rho alpha 2.57 +/-0.04 (R2 = 0.965, PD = 46.7). Power models of bone stiffness and strength, incorporating only low density data (rho alpha < 0.2 g cm-3, rho a < 0.3), were characterized by approximately squared exponents and these models underestimated the stiffness (five-fold) and overestimated the strength (two-fold) for higher density data, which were characterized by exponents greater than two. Using a subset of the data based upon an apparent dry density range of 0.22 < rho a < 1.89 g cm-3, it was possible to obtain a mathematical relationship in which bone stiffness and strength were precisely proportional to the cube and square, respectively, of the apparent dry density. These results indicate that the mathematical dependency of bone compressive mechanical properties on composition is closely dependent upon the density and mineral content range examined and, in terms of a single compositional measure, is best predicted by apparent ash density expressed as a power function.

Entities:  

Mesh:

Year:  1994        PMID: 7929465     DOI: 10.1016/0021-9290(94)90056-6

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  94 in total

1.  Changes in proximal femur bone properties following ovariectomy and their association with resistance to fracture.

Authors:  Hélder Fonseca; Daniel Moreira-Gonçalves; Mário Vaz; Maria Helena Fernandes; Rita Ferreira; Francisco Amado; Maria Paula Mota; José Alberto Duarte
Journal:  J Bone Miner Metab       Date:  2011-09-21       Impact factor: 2.626

2.  Fatigue characterization of a polymer foam to use as a cancellous bone analog material in the assessment of orthopaedic devices.

Authors:  V Palissery; M Taylor; M Browne
Journal:  J Mater Sci Mater Med       Date:  2004-01       Impact factor: 3.896

3.  The Effect of Quantitative Computed Tomography Acquisition Protocols on Bone Mineral Density Estimation.

Authors:  Hugo Giambini; Dan Dragomir-Daescu; Paul M Huddleston; Jon J Camp; Kai-Nan An; Ahmad Nassr
Journal:  J Biomech Eng       Date:  2015-11       Impact factor: 2.097

4.  In situ parameter identification of optimal density-elastic modulus relationships in subject-specific finite element models of the proximal femur.

Authors:  Alexander Cong; Jorn Op Den Buijs; Dan Dragomir-Daescu
Journal:  Med Eng Phys       Date:  2010-10-27       Impact factor: 2.242

Review 5.  A biomechanical perspective on bone quality.

Authors:  C J Hernandez; T M Keaveny
Journal:  Bone       Date:  2006-07-28       Impact factor: 4.398

6.  Mechanical properties of open-cell foam synthetic thoracic vertebrae.

Authors:  Amy E Johnson; Tony S Keller
Journal:  J Mater Sci Mater Med       Date:  2007-09-20       Impact factor: 3.896

7.  Apparent density patterns in subchondral bone of the sloth and anteater forelimb.

Authors:  Biren A Patel; Kristian J Carlson
Journal:  Biol Lett       Date:  2008-10-23       Impact factor: 3.703

Review 8.  Advanced CT based in vivo methods for the assessment of bone density, structure, and strength.

Authors:  K Engelke; C Libanati; T Fuerst; P Zysset; H K Genant
Journal:  Curr Osteoporos Rep       Date:  2013-09       Impact factor: 5.096

9.  Evaluating the Effect of Minimizing Screws on Stabilization of Symphysis Mandibular Fracture by 3D Finite Element Analysis.

Authors:  Ghias Kharmanda; Mohamed-Yaser Kharma
Journal:  J Maxillofac Oral Surg       Date:  2016-04-21

10.  Significance of preoperative planning for prophylactic augmentation of osteoporotic hip: A computational modeling study.

Authors:  Amirhossein Farvardin; Ehsan Basafa; Mahsan Bakhtiarinejad; Mehran Armand
Journal:  J Biomech       Date:  2019-07-19       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.