Literature DB >> 7927390

Ferromagnetic high-permeability alloy alone can provide sufficient low-frequency and eddy-current shieldings for biomagnetic measurements.

Y C Okada1, B Shah, J C Huang.   

Abstract

A low cost, two-shell ferromagnetic shielded room large enough for a person to enter and prepare experiments was constructed for biomagnetic measurements. No aluminium or copper shell was used for eddy-current shielding. A high-permeability nickel-iron-molybdenum alloy (1.57 mm thick) was used for both ferromagnetic and eddy-current shieldings. The shielding factor was 60 dB at dc and 40 dB between 0.1 Hz and about 3 Hz. The eddy-current shielding due to the alloy alone provided a shielding factor of 55 dB at 30 Hz and 66 dB at 60 Hz. The shielding factor was sufficiently high in all the frequency range for biomagnetic measurements with a first-order superconducting gradiometer.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7927390     DOI: 10.1109/10.301736

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  2 in total

1.  Invariance in current dipole moment density across brain structures and species: physiological constraint for neuroimaging.

Authors:  Shingo Murakami; Yoshio Okada
Journal:  Neuroimage       Date:  2015-02-10       Impact factor: 6.556

2.  Physiological origins of evoked magnetic fields and extracellular field potentials produced by guinea-pig CA3 hippocampal slices.

Authors:  Shingo Murakami; Tongsheng Zhang; Akira Hirose; Yoshio C Okada
Journal:  J Physiol       Date:  2002-10-01       Impact factor: 5.182

  2 in total