Adaptive digital notch filter design on the unit circle for the removal of powerline noise from biomedical signals.

M Ferdjallah1, R E Barr.   

Abstract

This paper investigates adaptive digital notch filters for the elimination of powerline noise from biomedical signals. Since the distribution of the frequency variation of the powerline noise may or may not be centered at 60 Hz, three different adaptive digital notch filters are considered. For the first case, an adaptive FIR second-order digital notch filter is designed to track the center frequency variation. For the second case, the zeroes of an adaptive IIR second-order digital notch filter are fixed on the unit circle and the poles are adapted to find an optimum bandwidth to eliminate the noise to a pre-defined attenuation level. In the third case, both the poles and zeroes of the adaptive IIR second-order filter are adapted to track the center frequency variation within an optimum bandwidth. The adaptive process is considerably simplified by designing the notch filters by pole-zero placement on the unit circle using some suggested rules. A constrained least mean-squared (CLMS) algorithm is used for the adaptive process. To evaluate their performance, the three adaptive notch filters are applied to a powerline noise sample and to a noisy EEG as an illustration of a biomedical signal.

Mesh:

Year:  1994        PMID: 7927372     DOI: 10.1109/10.293240

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  5 in total

1.  Adaptive HIFU noise cancellation for simultaneous therapy and imaging using an integrated HIFU/imaging transducer.

Authors:  Jong Seob Jeong; Jonathan Matthew Cannata; K Kirk Shung
Journal:  Phys Med Biol       Date:  2010-03-12       Impact factor: 3.609

2.  Feasible pickup from intact ossicular chain with floating piezoelectric microphone.

Authors:  Hou-Yong Kang; Gao Na; Fang-Lu Chi; Kai Jin; Tie-Zheng Pan; Zhen Gao
Journal:  Biomed Eng Online       Date:  2012-02-22       Impact factor: 2.819

3.  A non-invasive method to predict electrical cardioversion outcome of persistent atrial fibrillation.

Authors:  Raúl Alcaraz; José Joaquín Rieta
Journal:  Med Biol Eng Comput       Date:  2008-04-24       Impact factor: 2.602

4.  A combined algorithm for T-wave alternans qualitative detection and quantitative measurement.

Authors:  XiangKui Wan; Kanghui Yan; Dehan Luo; Yanjun Zeng
Journal:  J Cardiothorac Surg       Date:  2013-01-14       Impact factor: 1.637

5.  Powerline noise elimination in biomedical signals via blind source separation and wavelet analysis.

Authors:  Samuel Akwei-Sekyere
Journal:  PeerJ       Date:  2015-07-02       Impact factor: 2.984

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.