Literature DB >> 7886853

Assessment of colour Doppler tissue imaging using test-phantoms.

A D Fleming1, W N McDicken, G R Sutherland, P R Hoskins.   

Abstract

An investigation has been carried out on the velocity resolution, spatial resolution and accuracy of Doppler images as part of a study into the Doppler display of cardiac tissue motion. Test-phantoms were designed to perform this work and images were captured on a computer. The characteristics of the phantom images and of the image capture process were studied. The smallest spatial detail that was observed in the Doppler image was 3 mm by 3 mm. Doppler receive gain and Doppler ensemble size both affected velocity resolution. Different target materials gave different measures for velocity resolution. This could be related to the different back-scatter intensities of the materials.

Mesh:

Year:  1994        PMID: 7886853     DOI: 10.1016/0301-5629(94)90053-1

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  6 in total

Review 1.  Developments in cardiovascular ultrasound. Part 3: Cardiac applications.

Authors:  C M Moran; W N McDicken; P R Hoskins; P J Fish
Journal:  Med Biol Eng Comput       Date:  1998-09       Impact factor: 2.602

2.  Doppler myocardial imaging in the assessment of normal and ischemic myocardial function--past, present and future.

Authors:  J M Strotmann; L Hatle; G R Sutherland
Journal:  Int J Cardiovasc Imaging       Date:  2001-04       Impact factor: 2.357

3.  Tissue Doppler imaging and the quantification of myocardial function.

Authors:  R Rambaldi; D Poldermans; W B Vletter; J J Bax; J R Roelandt
Journal:  Int J Card Imaging       Date:  1998-08

4.  Does Doppler myocardial imaging give new insights or simply old information revisited?

Authors:  G R Sutherland; A Lange; P Palka; N Grubb; A Fleming; W N McDicken
Journal:  Heart       Date:  1996-09       Impact factor: 5.994

5.  Assessment of atrial septal defect morphology by transthoracic three dimensional echocardiography using standard grey scale and Doppler myocardial imaging techniques: comparison with magnetic resonance imaging and intraoperative findings.

Authors:  A Lange; M Walayat; C M Turnbull; P Palka; P Mankad; G R Sutherland; M J Godman
Journal:  Heart       Date:  1997-10       Impact factor: 5.994

6.  Electromechanical relationship in hypertrophic cardiomyopathy.

Authors:  Xiaoping Lin; Hsin-Yueh Liang; Aurelio Pinheiro; Veronica Dimaano; Lars Sorensen; Miguel Aon; Larisa G Tereshchenko; Yihan Chen; Meixiang Xiang; Theodore P Abraham; M Roselle Abraham
Journal:  J Cardiovasc Transl Res       Date:  2013-06-15       Impact factor: 4.132

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.