Literature DB >> 7880990

Comparison of cardiac output measurement by continuous thermodilution with electromagnetometry in adult cardiac surgical patients.

C W Hogue1, M Rosenbloom, C McCawley, D G Lappas.   

Abstract

A pulmonary artery catheter (PAC) capable of continuous cardiac output (CCO) determination by thermodilution has recently been introduced. The purpose of this study was to compare CCO with two other methods of cardiac output (Ot) determination: electromagnetometry (EM) and standard bolus thermodilution cardiac output (BCO). Following median sternotomy and pericardiotomy, an EM ring probe was placed around the ascending aorta in 25 adult cardiac surgical patients and connected to an EM flowmeter interfaced with a calibrated strip recorder. Measurements were obtained over a 15- to 20-minute interval during a period of stable EM-determined Ot prior to initiation of cardiopulmonary bypass and in the absence of surgical stimulation. The CCO system averages Ot over a 3-minute interval, updating the measurement every 30 seconds. Cardiac output determined by the CCO system was compared with EM Ot averaged from the prior 3-minute period and with BCO obtained immediately after changing the Ot monitor from the continuous to bolus mode. Compared with EM, the bias for CCO was -0.48 L/min, precision 0.56 L/min, and the limits of agreement 1.12 L/min. Bias, precision, and limits of agreement of CCO compared with BCO were 0.41, 0.82, 1.64 L/min, respectively. Correlation between EM and CCO was r = 0.80 and between CCO and BCO r = 0.64. Cardiac output determined by CCO was within 10% of the EM determination for 37 measurements, between 10% and 20% for 17, and greater than 20% for 7 measurements.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1994        PMID: 7880990     DOI: 10.1016/1053-0770(94)90193-7

Source DB:  PubMed          Journal:  J Cardiothorac Vasc Anesth        ISSN: 1053-0770            Impact factor:   2.628


  6 in total

Review 1.  [Measurement of cardiac output].

Authors:  D A Reuter; A E Goetz
Journal:  Anaesthesist       Date:  2005-11       Impact factor: 1.041

Review 2.  Methods in pharmacology: measurement of cardiac output.

Authors:  Bart F Geerts; Leon P Aarts; Jos R Jansen
Journal:  Br J Clin Pharmacol       Date:  2011-03       Impact factor: 4.335

3.  Agreement between continuous and intermittent pulmonary artery thermodilution for cardiac output measurement in perioperative and intensive care medicine: a systematic review and meta-analysis.

Authors:  Karim Kouz; Frederic Michard; Alina Bergholz; Christina Vokuhl; Luisa Briesenick; Phillip Hoppe; Moritz Flick; Gerhard Schön; Bernd Saugel
Journal:  Crit Care       Date:  2021-03-29       Impact factor: 9.097

4.  The uncalibrated pulse contour cardiac output during off-pump coronary bypass surgery: performance in patients with a low cardiac output status and a reduced left ventricular function.

Authors:  Youn Yi Jo; Jong Wook Song; Young Chul Yoo; Ji Young Park; Jae Kwang Shim; Young Lan Kwak
Journal:  Korean J Anesthesiol       Date:  2011-04-26

Review 5.  Clinical relevance of data from the pulmonary artery catheter.

Authors:  Emmanuel Robin; Marion Costecalde; Gilles Lebuffe; Benoît Vallet
Journal:  Crit Care       Date:  2006       Impact factor: 9.097

Review 6.  The contemporary pulmonary artery catheter. Part 2: measurements, limitations, and clinical applications.

Authors:  I T Bootsma; E C Boerma; T W L Scheeren; F de Lange
Journal:  J Clin Monit Comput       Date:  2021-03-01       Impact factor: 2.502

  6 in total