Laboratory and bedside evaluation of portable glucose meters.

J H Nichols1, C Howard, K Loman, C Miller, D Nyberg, D W Chan.   

Abstract

A two-phase, laboratory and bedside, evaluation of blood glucose meters was conducted in this study. Four meters, the AccuData Easy (Boehringer-Mannheim, Indianapolis, IN), HemoCue Glucose (HemoCue, Mission Viejo, CA), LifeScan One Touch II (LifeScan, Milpitas, CA), and Miles Encore QA (Miles, Elkhart, IN) systems, were compared to the Nova Stat Profile 5 (Nova, Waltham, MA) as the laboratory reference. Precision, linearity, correlation to the laboratory method, interference from hematocrit, data management, and operator preference were examined. None of the meters were found to satisfy all of the study's evaluation criteria. Therefore, institutions must weigh which criteria are most important to their individual settings. Although the HemoCue Glucose was found to be technically superior, this meter had no data management capabilities. The Encore QA had greater variance and low bias, whereas the AccuData Easy had bias affected by hematocrit and glucose concentration, and the One Touch II had a negative hematocrit bias and limited linear range when compared to the Nova. Only meters meeting both minimal analytical performance and computerization requirements, the One Touch II and AccuData Easy, were selected for further evaluation. At the bedside, the One Touch II demonstrated performance consistent with the lab evaluation, whereas the AccuData Easy showed greater imprecision in the low glucose range and a correlation that varied with sample type: capillary, venous, or arterial blood. This evaluation indicates that the clinician must interpret near-patient glucose results with respect to meter limitations. FDA approval and marketing statistics, alone, are insufficient to judge the performance of the meters in routine institutional use. Independent method validation, under actual operating conditions, is a better means of predicting future performance of the meters.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7856571     DOI: 10.1093/ajcp/103.2.244

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  4 in total

1.  Near patient testing: is it here to stay?

Authors:  J M Hicks
Journal:  J Clin Pathol       Date:  1996-03       Impact factor: 3.411

2.  Evaluation of hematocrit interference with MyStar extra and seven competitive devices.

Authors:  Filiz Demircik; Sanja Ramljak; Iris Hermanns; Anke Pfützner; Andreas Pfützner
Journal:  J Diabetes Sci Technol       Date:  2014-12-30

3.  Frontal lobe regulation of blood glucose levels: support for the limited capacity model in hostile violence-prone men.

Authors:  Robert P Walters; Patti Kelly Harrison; Ransom W Campbell; David W Harrison
Journal:  Brain Inform       Date:  2016-02-01

4.  Evaluation of newly developed veterinary portable blood glucose meter with hematocrit correction in dogs and cats.

Authors:  Akihiro Mori; Hitomi Oda; Eri Onozawa; Saori Shono; Toshinori Sako
Journal:  J Vet Med Sci       Date:  2017-08-18       Impact factor: 1.267

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.