Literature DB >> 7853732

Quantitative analysis of changes of automated perimetric thresholds after pupillary dilation and induced myopia in normal subjects.

H J Park1, D H Youn.   

Abstract

We quantitatively analyzed the changes of the (retinal) threshold sensitivities between normal status and dilated emmetropic status, and between dilated emmetropic status and -1.0D induced myopic status. Three consecutive visual field examinations by Humphrey Field Analyzer C-30-2 threshold test and STATPAC program were performed in 36 eyes of 21 normal subjects who ranged in age from 23 to 40 years. The results were as follows: 1) There was a statistically significant decrease (0.87 +/- 0.91dB)in the mean threshold sensitivity within the central 30 degrees at the dilated emmetropic status (27.90dB) as compared with the normal status (28.77dB)(p = 0.0001). 2) There was a statistically significant decrease(0.99 +/- 0.61dB) at -1.0D induced myopic status(26.91dB) as compared with the dilated emmetropic status(27.90dB)(p = 0.0001). 3) After dilation, the mean threshold sensitivity between 20 and 30 degrees of field showed statistically significant decrease as compared with those within the central 20 degrees of visual field(p < 0.05). In case of -1.0D induced myopia, there were uniform decreases in the mean threshold sensitivities within the central 30 degrees of visual field (p > 0.05). Therefore, we emphasize the importance of consistent pupillary size and correct refractive state in performing the serial automated visual field tests.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7853732     DOI: 10.3341/kjo.1994.8.2.53

Source DB:  PubMed          Journal:  Korean J Ophthalmol        ISSN: 1011-8942


  3 in total

1.  Effects of mydriasis and miosis on kinetic perimetry findings in normal participants.

Authors:  Kazunori Hirasawa; Nobuyuki Shoji; Chieko Kobashi; Ayaka Yamanashi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-05-19       Impact factor: 3.117

2.  Validation of a Tablet as a Tangent Perimeter.

Authors:  Algis J Vingrys; Jessica K Healey; Sheryl Liew; Veera Saharinen; Michael Tran; William Wu; George Y X Kong
Journal:  Transl Vis Sci Technol       Date:  2016-07-14       Impact factor: 3.283

3.  Effect of Pharmacological Pupil Dilation on Dark-Adapted Perimetric Sensitivity in Healthy Subjects Using an Octopus 900 Perimeter.

Authors:  Austin D Igelman; Cristy Ku; Sam Mershon; Mariana Matioli da Palma; J Jason McAnany; Robert A Hyde; Jason C Park; Paul Yang; Mark E Pennesi
Journal:  Transl Vis Sci Technol       Date:  2021-12-01       Impact factor: 3.283

  3 in total