Literature DB >> 7837334

Prenatal visualization of cranial sutures and fontanelles with three-dimensional ultrasonography.

D H Pretorius1, T R Nelson.   

Abstract

The anatomy of the cranial sutures and fontanelles in the developing fetus is difficult to evaluate using conventional two-dimensional ultrasonography (2DUS). Three-dimensional sonographic imaging (3DUS) was performed on eight normal volunteer pregnant patients after informed consent with conventional 2DUS equipment that had been adapted to obtain 3DUS images. 3DUS images of the cranium were evaluated for the presence of specific cranial sutures and fontanelles. Cranial sutures and fontanelles were identified with 3DUS in all fetuses scanned. The sutures most commonly identified included coronal, lambdoidal, and squamosal. The fontanelles most often identified included anterior, posterior, mastoid, and sphenoid. 3DUS offers the capability of identifying cranial sutures and fontanelles more clearly because volume rendered images show the cranial surface in its entirely rather than as a cross-sectional slice, offering the potential to identify pathologic cranial lesions currently not seen with 2DUS.

Entities:  

Mesh:

Year:  1994        PMID: 7837334     DOI: 10.7863/jum.1994.13.11.871

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  7 in total

1.  The value of three-dimensional ultrasonography in the screening of the fetal skeleton.

Authors:  Bernard Benoit
Journal:  Childs Nerv Syst       Date:  2003-07-12       Impact factor: 1.475

Review 2.  Three-dimensional ultrasound of the fetus: how does it help?

Authors:  Luis F Gonçalves
Journal:  Pediatr Radiol       Date:  2016-01-29

Review 3.  Three- and 4-dimensional ultrasound in obstetric practice: does it help?

Authors:  Luís F Gonçalves; Wesley Lee; Jimmy Espinoza; Roberto Romero
Journal:  J Ultrasound Med       Date:  2005-12       Impact factor: 2.153

Review 4.  Evolution of fetal ultrasonography.

Authors:  F E Avni; T Cos; M Cassart; A Massez; C Donner; K Ismaili; M Hall
Journal:  Eur Radiol       Date:  2006-05-30       Impact factor: 5.315

5.  Three-dimensional ultrasound scanning.

Authors:  Aaron Fenster; Grace Parraga; Jeff Bax
Journal:  Interface Focus       Date:  2011-06-01       Impact factor: 3.906

6.  The place of four-dimensional ultrasound in evaluating fetal anomalies.

Authors:  D F Öcal; T Nas; I Güler
Journal:  Ir J Med Sci       Date:  2014-08-21       Impact factor: 1.568

Review 7.  A guide to the recognition of skeletal disorders in the fetus.

Authors:  Rita L Teele
Journal:  Pediatr Radiol       Date:  2006-03-09
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.