Literature DB >> 7831693

Carotid Stenosis Index. A new method of measuring internal carotid artery stenosis.

C F Bladin1, A V Alexandrov, J Murphy, R Maggisano, J W Norris.   

Abstract

BACKGROUND AND
PURPOSE: Current methods of measuring carotid stenosis such as those used in the North American Symptomatic Carotid Endarterectomy Trial (NASCET) and European Carotid Surgery Trial (ECST) have limitations caused by difficulties in measuring the normal width of the distal internal carotid artery (ICA) or the carotid bulb.
METHODS: We developed a new technique, the Carotid Stenosis Index (CSI), based on the known anatomic relationship between the common carotid artery (CCA) and ICA (1.2 x CCA diameter=proximal ICA diameter). The normal ICA diameter can therefore be calculated from direct measurement of the CCA. Three blinded observers evaluated the angiograms of 57 patients (114 carotid arteries), previously screened with duplex ultrasonography, using the NASCET, ECST, and CSI methods. In a subset of 30 patients undergoing carotid endarterectomy, comparison was also made to computerized carotid plaque planimetry.
RESULTS: The NASCET method could only be applied correctly in 89% and the ECST method in 95% of cases because of overlying vessels or inadequate views of the distal ICA or carotid bulb. An additional 9% of NASCET cases had a "negative" stenosis, in which the stenosis is wider than the distal ICA. The CSI method was applicable in 99% of cases. Interobserver comparison using ANOVA revealed significant differences using NASCET (P < .0001) and ECST (P <.001) but not CSI (P = NS). NASCET had a sevenfold variation (P < .01) and ECST a twofold variation (P < .01) in results compared with CSI. The intraobserver reliability was 0.87 for NASCET, 0.86 for ECST, and 0.90 for CSI. However, the 95% confidence intervals for an individual measurement by an observer were +/- 30% for NASCET, +/- 19% for ECST, and +/- 15% for CSI. With linear methods of measurement there were significant differences between NASCET and CSI (P < .0001) and ECST (P < .0001) but not between CSI and ECST. A comparison of area derivations of these methods to carotid plaque planimetry revealed significant differences from NASCET (P <.0001) but not ECST, CSI, or duplex methods. A CSI nomogram was created, allowing measurement of both linear and area percent stenosis.
CONCLUSIONS: CSI is the most reliable validated method of measuring carotid stenosis, and it correlates with duplex and carotid pathology.

Entities:  

Mesh:

Year:  1995        PMID: 7831693     DOI: 10.1161/01.str.26.2.230

Source DB:  PubMed          Journal:  Stroke        ISSN: 0039-2499            Impact factor:   7.914


  8 in total

1.  A Method for Quantifying Angiographic Severity of Extracranial Vertebral Artery Stenosis.

Authors:  Adnan I Qureshi
Journal:  J Vasc Interv Neurol       Date:  2015-05

2.  Carotid duplex ultrasound and transcranial Doppler findings in commercial divers and pilots.

Authors:  Banafshe Dormanesh; Kia Vosoughi; Fahimeh H Akhoundi; Masoud Mehrpour; Seyed-Mohammad Fereshtehnejad; Setareh Esmaeili; Azin Shafiee Sabet
Journal:  Neurol Sci       Date:  2016-07-26       Impact factor: 3.307

3.  Image-based assessment of uncertainty in quantification of carotid lumen.

Authors:  Lilli Kaufhold; Andreas Harloff; Christian Schumann; Axel J Krafft; Juergen Hennig; Anja Hennemuth
Journal:  J Med Imaging (Bellingham)       Date:  2018-09-24

Review 4.  Duplex ultrasound for diagnosing symptomatic carotid stenosis in the extracranial segments.

Authors:  Nicolle Cassola; Jose Cc Baptista-Silva; Luis Cu Nakano; Carolina Dq Flumignan; Ricardo Sesso; Vladimir Vasconcelos; Nelson Carvas Junior; Ronald Lg Flumignan
Journal:  Cochrane Database Syst Rev       Date:  2022-07-11

5.  Increased tissue factor, MMP-8, and D-dimer expression in diabetic patients with unstable advanced carotid atherosclerosis.

Authors:  Jerzy Krupinski; Marta M Turu; M Angels Font; Nesser Ahmed; Matthew Sullivan; Francisco Rubio; Lina Badimon; Mark Slevin
Journal:  Vasc Health Risk Manag       Date:  2007

6.  Risk Factors for Residual Stenosis After Carotid Artery Stenting.

Authors:  Yunlu Tao; Yang Hua; Lingyun Jia; Liqun Jiao; Beibei Liu
Journal:  Front Neurol       Date:  2021-01-28       Impact factor: 4.003

7.  Dual-pass feature extraction on human vessel images.

Authors:  W Hernandez; S Grimm; R Andriantsimiavona
Journal:  J Digit Imaging       Date:  2013-11-06       Impact factor: 4.056

8.  Unilateral congenital elongation of the cervical part of the internal carotid artery with kinking and looping: two case reports and review of the literature.

Authors:  Nikolai A Ovchinnikov; Ramesh T Rao; Suresh R Rao
Journal:  Head Face Med       Date:  2007-07-25       Impact factor: 2.151

  8 in total