Literature DB >> 7816290

Assessment of refill and hypovolaemia by continuous surveillance of blood volume and extracellular fluid volume.

H J Bogaard1, J P de Vries, P M de Vries.   

Abstract

During renal replacement therapy hypovolaemia due to ultrafiltration (UF) may, when not sufficiently counteracted by refill from the interstitium, result in hypotension. Combining two recently developed methods the haemodynamic process of refill was studied in order to find characteristics featuring hypotension. Relative blood volume (BV) and extracellular fluid volume (EFV) were measured continuously in 40 stable haemodialysis patients by means of an optical and a conductivity technique respectively. Regarding their postdialytic (PD) EFV the patients were divided into three groups: normohydrated (N, n = 20), dehydrated (D, n = 11) and overhydrated (O, n = 9). Significant differences between the groups were assessed in BV decrease (after 2 h until the end of treatment P < 0.05 and after 3 h P < 0.01), EFV decrease (after 3 h P < 0.05) and occurrence of hypotensive episodes (N,5; D,7; O,none; P < 0.01). During the entire session the speed of BV decrease was significantly higher in hypotensive patients (H) than in non-hypotensive patients (non-H). At the moment of hypotension (after 141 +/- 49 min) residual BV was less (P < 0.0005) in H (87.7 +/- 5.2%) than at the corresponding moment in non-H patients (96.5 +/- 4.0%). PD BV and PD EFV, both expressed as a percentage of the starting value, correlated significantly (r = 0.63, p < 0.005) and UF-volume (differences between the groups were not significant) correlated to EFV decrease (r = 0.45, P < 0.005). In conclusion, the combination of both non-invasive methods elucidates the pathophysiology of UF-induced hypotension and provides a means of reducing dialysis morbidity. The influence of tissue hydration state on these variables has been shown.

Entities:  

Mesh:

Year:  1994        PMID: 7816290

Source DB:  PubMed          Journal:  Nephrol Dial Transplant        ISSN: 0931-0509            Impact factor:   5.992


  6 in total

1.  Validity of exchangeable solute balance as a measure of blood volume in neurologically injured adults.

Authors:  Aaron M Joffe; Lawrence Healey; Nita Khandelwal; Matthew R Hallman; William Van Cleve; Miriam M Treggiari
Journal:  Neurocrit Care       Date:  2014-08       Impact factor: 3.210

2.  Bioimpedance monitoring of cellular hydration during hemodialysis therapy.

Authors:  Leslie D Montgomery; Richard W Montgomery; Wayne A Gerth; Susie Q Lew; Michael D Klein; Julian M Stewart; Marvin S Medow; Manuel T Velasquez
Journal:  Hemodial Int       Date:  2016-11-08       Impact factor: 1.543

3.  Effects of the intermittent pneumatic circulator on blood pressure during hemodialysis.

Authors:  Tzu-Chao Hsu; Ya-Ju Chang; Yu-Yao Huang; Miao-Ju Hsu
Journal:  Sensors (Basel)       Date:  2010-11-09       Impact factor: 3.576

4.  Study protocol for a single-blind, placebo-controlled randomised trial of Tianjiu effects in patients with intradialytic hypotension.

Authors:  Ming-Yen Tsai; Yu-Jen Su; Hwee-Yeong Ng; Shih-Yu Chen; Yu-Chuen Huang; Chien-Hsing Wu; Yung-Hsiang Chen
Journal:  BMJ Open       Date:  2016-03-10       Impact factor: 2.692

5.  Association of intradialytic hypotension and convective volume in hemodiafiltration: results from a retrospective cohort study.

Authors:  Franklin G Mora-Bravo; Guadalupe De-La-Cruz; Sonia Rivera; Alfonso Mariscal Ramírez; Jochen G Raimann; Héctor Pérez-Grovas
Journal:  BMC Nephrol       Date:  2012-09-10       Impact factor: 2.388

6.  Intraoperative Fluid Restriction is Associated with Functional Delayed Graft Function in Living Donor Kidney Transplantation: A Retrospective Cohort Analysis.

Authors:  Gertrude J Nieuwenhuijs-Moeke; Tobias M Huijink; Robert A Pol; Mostafa El Moumni; Johannes Gm Burgerhof; Michel Mrf Struys; Stefan P Berger
Journal:  J Clin Med       Date:  2019-10-02       Impact factor: 4.241

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.