Literature DB >> 24057812

Validity of exchangeable solute balance as a measure of blood volume in neurologically injured adults.

Aaron M Joffe1, Lawrence Healey, Nita Khandelwal, Matthew R Hallman, William Van Cleve, Miriam M Treggiari.   

Abstract

BACKGROUND: Daily weight (DW) and examination of fluid balances (FB) are commonly used in assessments of extracellular fluid (ECF) and circulating blood volume (BV). We hypothesized that a calculated total body exchangeable solute, the main determinant of the ECF, would have high agreement and correlation with actual BV.
METHODS: The University of Washington IRB approved the study. We included a sample of consecutive adult patients in whom a BV was measured, while in the neuroscience intensive care units of a large academic medical center. BV was measured as part of routine care using iodinated (131)I albumin injection and the BVA-100 (Daxor Corp, New York, NY, USA). Total body exchangeable solute was estimated at the time of BV measurement by multiplying the calculated total body water by the sum of the sodium plus potassium and chloride measured in plasma. The correlation between the change in DW, FB (adjusted for insensible fluid loss), exchangeable solute, and BV was performed using linear regression with adjustment for number of days between admit and BV measurement, and capillary leak. Errors were computed using robust variance estimation.
RESULTS: 55 patients had BV tests available, and 43 of them had subarachnoid hemorrhage. Total body exchangeable solute strongly correlated with BV (r = 0.75, 95% CI 0.63-0.84, p < 0.01 for Na(+)/K(+), and r = 0.71, 95% CI 0.58-0.81, p < 0.01 for Cl(-)). DW (r = 0.21) and FB (r = 0.11) were not correlated with BV.
CONCLUSIONS: Total body exchangeable solute appears to be a valid and reliable measure of BV and can be calculated using information readily available at the bedside. The value of having this information automatically calculated and available at the bedside should be explored.

Entities:  

Mesh:

Year:  2014        PMID: 24057812     DOI: 10.1007/s12028-013-9915-1

Source DB:  PubMed          Journal:  Neurocrit Care        ISSN: 1541-6933            Impact factor:   3.210


  20 in total

1.  Colloid oncotic pressure and body water dynamics in septic and injured patients.

Authors:  C E Lucas; A M Ledgerwood; W J Rachwal; D Grabow; J M Saxe
Journal:  J Trauma       Date:  1991-07

Review 2.  The paradox of sodium's volume of distribution. Why an extracellular solute appears to distribute over total body water.

Authors:  A Spital; R D Sterns
Journal:  Arch Intern Med       Date:  1989-06

3.  Fluid balance in critically ill patients. Should we really rely on it?

Authors:  A Perren; M Markmann; G Merlani; C Marone; P Merlani
Journal:  Minerva Anestesiol       Date:  2011-08       Impact factor: 3.051

4.  Actively circulating blood volume in endotoxin shock measured by indicator dilution.

Authors:  C F Rothe; R H Murray; T D Bennett
Journal:  Am J Physiol       Date:  1979-02

Review 5.  Insensible water loss and its assessment in adult patients: a review.

Authors:  P Cox
Journal:  Acta Anaesthesiol Scand       Date:  1987-11       Impact factor: 2.105

6.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

7.  Plasma and blood volumes in patients with the nephrotic syndrome.

Authors:  A B Geers; H A Koomans; P Boer; E J Dorhout Mees
Journal:  Nephron       Date:  1984       Impact factor: 2.847

8.  Total body water volumes for adult males and females estimated from simple anthropometric measurements.

Authors:  P E Watson; I D Watson; R D Batt
Journal:  Am J Clin Nutr       Date:  1980-01       Impact factor: 7.045

Review 9.  Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares.

Authors:  Paul E Marik; Michael Baram; Bobbak Vahid
Journal:  Chest       Date:  2008-07       Impact factor: 9.410

10.  Circulating blood volume measurements correlate poorly with pulmonary artery catheter measurements.

Authors:  Hideko Yamauchi; Elisabeth N Biuk-Aghai; Mihae Yu; Hao Chih Ho; Alyssa D Chapital; Wega Koss; Danny M Takanishi
Journal:  Hawaii Med J       Date:  2008-01
View more
  1 in total

1.  Assessment of circulating blood volume with fluid administration targeting euvolemia or hypervolemia.

Authors:  Aaron M Joffe; Nita Khandelwal; Matthew R Hallman; Miriam M Treggiari
Journal:  Neurocrit Care       Date:  2015-02       Impact factor: 3.210