Literature DB >> 7800386

Exposure parameters and their effects on diagnostic accuracy.

B Svenson1, U Welander, G Anneroth, B Söderfeldt.   

Abstract

A new method for analyzing diagnostic accuracy is introduced. A diagnostic accuracy curve may be obtained by plotting receiver operating characteristic analysis data, P(A), as a function of exposure. By means of diagnostic accuracy curves the effects on diagnostic accuracy of tube potential, exposure, and size of carious lesions was studied. It was found that the effect of the tube potential on the accuracy of caries diagnosis is negligible. About 25% of the variation in diagnostic accuracy depends on the exposure and about 80% on lesion depth. With the lesion depth constant, about 75% of the variance in diagnostic accuracy depended on observer performance. The peak of a diagnostic accuracy curve indicates optimum performance. This is found at an exposure that gives a radiographic density of about 1 in enamel and dentin although the tolerable exposure increases with increased lesion depth.

Entities:  

Mesh:

Year:  1994        PMID: 7800386     DOI: 10.1016/0030-4220(94)90050-7

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol        ISSN: 0030-4220


  8 in total

1.  Diagnostic accuracy of proximal enamel subsurface demineralization and its relationship with calcium loss and lesion depth.

Authors:  E Onem; B G Baksi; B H Sen; O Sögüt; A Mert
Journal:  Dentomaxillofac Radiol       Date:  2011-11-10       Impact factor: 2.419

2.  Effect of tube potential and image receptor on the detection of natural proximal caries in primary teeth.

Authors:  Elif Sogur; B Güniz Baksı; Kaan Orhan; S Candan Paksoy; Salih Dogan; Yılmaz S Erdal; Ali Mert
Journal:  Clin Oral Investig       Date:  2010-09-14       Impact factor: 3.573

3.  Effect of Different Tube Potential Settings on Caries Detection using PSP Plate and Conventional Film.

Authors:  Daniela Pita De Melo; Adriana Dibo Cruz; Saulo Leonardo Sousa Melo; Julyanna Filgueiras GonçAlves De Farias; Francisco Haiter-Neto; Solange Maria De Almeida
Journal:  J Clin Diagn Res       Date:  2015-04-01

4.  Determination of optimum exposure parameters for dentoalveolar structures of the jaws using the CB MercuRay system with cluster signal-to-noise analysis.

Authors:  Warangkana Weerawanich; Mayumi Shimizu; Yohei Takeshita; Kazutoshi Okamura; Shoko Yoshida; Gainer R Jasa; Kazunori Yoshiura
Journal:  Oral Radiol       Date:  2018-09-14       Impact factor: 1.852

5.  Effects of exposure parameters and slice thickness on detecting clear and unclear mandibular canals using cone beam CT.

Authors:  Gainer R Jasa; Mayumi Shimizu; Kazutoshi Okamura; Kenji Tokumori; Yohei Takeshita; Warangkana Weerawanich; Kazunori Yoshiura
Journal:  Dentomaxillofac Radiol       Date:  2017-02-17       Impact factor: 2.419

6.  Effect of changing the kilovoltage peak on radiographic caries assessment in digital and conventional radiography.

Authors:  Mohamed Khalifa Zayet; Yara Rabee Helaly; Salma Belal Eiid
Journal:  Imaging Sci Dent       Date:  2014-09-17

7.  In vitro evaluation of proximal carious lesions using digital radiographic systems.

Authors:  Mayana Soares Vieira; Caroline Parente Ribeiro Nogueira; Marcos André dos Santos Silva; José Roberto de Oliveira Bauer; Etevaldo Matos Maia Filho
Journal:  ScientificWorldJournal       Date:  2015-01-27

8.  Effects of various cone-beam computed tomography settings on the detection of recurrent caries under restorations in extracted primary teeth.

Authors:  Kıvanç Kamburoğlu; Gül Sönmez; Zeynep Serap Berktaş; Hakan Kurt; Doĝukan Özen
Journal:  Imaging Sci Dent       Date:  2017-06-22
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.