Integrated implantable device for long-term glucose monitoring.

E Wilkins1, P Atanasov, B A Muggenburg.   

Abstract

In this study we report the development of an integrated implantable device for glucose monitoring. The dimensions of the device (5.0 x 7.0 x 1.5 cm) allow implantation under the abdominal skin of a large animal for in vivo evaluation of sensor performance. The experimental set-up includes amperometric glucose biosensor, a miniature potentiostat, an FM signal transmitter, a power supply and an antenna and receiver linked to a computer-based data acquisition system. The device performance was evaluated in vitro using a ten-day continuous test and other long-term operation experiments. The biosensor was tested in different model solutions that simulated the physiological environment in which it will be ultimately used. A linear response to glucose concentration was obtained up to 25 mM glucose, with a sensitivity of less than 0.5 microA/mM. The ability of the biosensor to measure glucose levels in serum was also tested, and a good correlation demonstrated between glucose serum levels measured by routine technique and those measured using the biosensor (R2 = 0.993; slope = 0.996). Initial results obtained from the short-term subcutaneous implantation of the sensor demonstrate its potential for the monitoring of glucose concentration in vivo.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7786472     DOI: 10.1016/0956-5663(95)96894-5

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  5 in total

1.  Microspheres prepared with PLGA blends for delivery of dexamethasone for implantable medical devices.

Authors:  Yan Wang; Bing Gu; Diane J Burgess
Journal:  Pharm Res       Date:  2013-08-15       Impact factor: 4.200

2.  Continuous amperometric monitoring of glucose in a brittle diabetic chimpanzee with a miniature subcutaneous electrode.

Authors:  J G Wagner; D W Schmidtke; C P Quinn; T F Fleming; B Bernacky; A Heller
Journal:  Proc Natl Acad Sci U S A       Date:  1998-05-26       Impact factor: 11.205

3.  A miniaturized transcutaneous system for continuous glucose monitoring.

Authors:  Robert A Croce; SanthiSagar Vaddiraju; Jun Kondo; Yan Wang; Liang Zuo; Kai Zhu; Syed K Islam; Diane J Burgess; Fotios Papadimitrakopoulos; Faquir C Jain
Journal:  Biomed Microdevices       Date:  2013-02       Impact factor: 2.838

4.  Foreign Body Reaction to Implantable Biosensors: Effects of Tissue Trauma and Implant Size.

Authors:  Yan Wang; Santhisagar Vaddiraju; Bing Gu; Fotios Papadimitrakopoulos; Diane J Burgess
Journal:  J Diabetes Sci Technol       Date:  2015-08-25

Review 5.  Long-acting preparations of exenatide.

Authors:  Yunpeng Cai; Liangming Wei; Liuqing Ma; Xiwen Huang; Anqi Tao; Zhenguo Liu; Weien Yuan
Journal:  Drug Des Devel Ther       Date:  2013-09-05       Impact factor: 4.162

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.