[Color-coded duplex ultrasonography in the diagnosis of renal artery stenosis].

F Speckamp1, D Vorwerk, K Schürmann, J H Risse, M Kilbinger, J Tacke, R W Günther.   

Abstract

PURPOSE: Colour-coded duplex sonography was performed for diagnosis of renal artery stenosis to define standards and criteria for stenosis.
MATERIAL AND METHODS: In 20 normotensive volunteers and 123 patients with arterial hypertension, bilateral intrarenal Doppler spectra were examined and the following parameters including side ratios were calculated: pulsatility index (PI), resistance index (RI), acceleration time index (AT) and acceleration index (AI).
RESULTS: In 29 of the 123 patients, angiography showed unilateral renal artery stenosis. Acceleration index (AI) was found as the most reliable parameter with a sensitivity of 100% and a specificity of about 94% for stenoses grading at least 70%.
CONCLUSIONS: Colour-coded duplex sonography can depict relevant stenoses reliably, but anatomical variations may limit its value as a single screening method. Colour-coded duplex sonography can be, therefore, recommended as an adjunct to angiography for assessment of haemodynamic relevance.

Entities:  

Mesh:

Year:  1995        PMID: 7772763     DOI: 10.1055/s-2007-1015908

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  1 in total

1.  [Screening and diagnosis for eliminating renovascular hypertension. Value of 24-hour blood pressure monitoring and color-coded duplex ultrasound diagnosis].

Authors:  K L Schulte; K P Spies; D van Gemmeren; T Lenz; R Gotzen; A Distler; F Fobbe
Journal:  Med Klin (Munich)       Date:  1997-06-15