Literature DB >> 7769449

Myocardial perfusion imaging with technetium-99m-Tc NOET: comparison with thallium-201 and coronary angiography.

D Fagret1, P Y Marie, F Brunotte, M Giganti, D Le Guludec, A Bertrand, J E Wolf, A Piffanelli, F Chossat, D Bekhechi.   

Abstract

UNLABELLED: We compared TcN-NOET [bis(N-ethoxy, N-ethyl dithiocarbamato)nitrido 99mTc] and 201Tl images to estimate the utility of this compound in the detection of coronary artery disease (CAD).
METHODS: Twenty-five patients undergoing cardiac catheterization had stress-redistribution-reinjection 201Tl SPECT imaging, stress-delayed (2, 4 and 6 hr postinjection) and rest-delayed (4 hr postinjection) TcN-NOET SPECT imaging.
RESULTS: Nineteen patients had coronary stenosis > or = 50% and six were normal. Stress TcN-NOET and 201Tl imaging were concordant for the presence of CAD in 22/25 patients (88%, kappa = 0.76 +/- 0.20). The overall sensitivity of TcN-NOET SPECT imaging was 74% (14/19 patients) and 68% (13/19 patients) for 201Tl SPECT imaging. The specificity was 100% (6/6 patients) for both techniques. The overall agreement of TcN-NOET and 201Tl for the presence of disease in individual coronary arteries was 96% (72/75 arteries, kappa = 0.92 +/- 0.16). Segmental analysis of stress images showed a concordance in 211/225 segments (94%, kappa = 0.82 +/- 0.09). Comparison of the 4-hr images showed a concordance between 201Tl and TcN-NOET in 21/23 patients. Following TcN-NOET injection at rest, seven patients had a defect on the initial images, which had normalized 4 hr postinjection in four patients (57%).
CONCLUSION: Perfusion imaging with TcN-NOET and 201Tl gives comparable diagnostic information in patients undergoing exercise testing for assessment of CAD. Because of the normalization of myocardial activity 4 hr after injection in some patients, we conclude that TcN-NOET is a potential technetium compound equivalent to 201Tl.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7769449

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  16 in total

1.  Technetium 99m-N-NOET: although not equivalent to thallium-201, it still offers new opportunities.

Authors:  A J Sinusas
Journal:  J Nucl Cardiol       Date:  2000 Mar-Apr       Impact factor: 5.952

2.  Proceedings of the 4th Invitational Wintergreen Conference. Wintergreen, Virginia, USA. July 12-14, 1998. Abstracts.

Authors: 
Journal:  J Nucl Cardiol       Date:  1999 Jan-Feb       Impact factor: 5.952

Review 3.  Comparison of Tl-201 with Tc-99m-labeled myocardial perfusion agents: technical, physiologic, and clinical issues.

Authors:  P Kailasnath; A J Sinusas
Journal:  J Nucl Cardiol       Date:  2001 Jul-Aug       Impact factor: 5.952

4.  Tc-99m N-NOET: Chronicle of a unique perfusion imaging agent and a missed opportunity?

Authors:  Gérald Vanzetto; Daniel Fagret; Catherine Ghezzi
Journal:  J Nucl Cardiol       Date:  2004 Nov-Dec       Impact factor: 5.952

5.  Myocardial viability: seeking relevance and redefinition.

Authors:  J A Arrighi; R Soufer
Journal:  J Nucl Cardiol       Date:  1998 Nov-Dec       Impact factor: 5.952

6.  Comparison between Tc-99m N-NOET and Tl-201 in the assessment of patients with known or suspected coronary artery disease.

Authors:  Paramjit Jeetley; Nikant K Sabharwal; Prem Soman; Chris Kinsey; Usha Raval; Uday Bhonsle; Avijit Lahiri
Journal:  J Nucl Cardiol       Date:  2004 Nov-Dec       Impact factor: 5.952

7.  Planar imaging of 99mTc-labeled (bis(N-ethoxy, N-ethyl dithiocarbamato) nitrido technetium[V]) can detect resting ischemia.

Authors:  G Johnson; K N Nguyen; Z Liu; P Gao; R Pasqualini; R D Okada
Journal:  J Nucl Cardiol       Date:  1997 May-Jun       Impact factor: 5.952

Review 8.  Dithiocarbamate complexes as radiopharmaceuticals for medical imaging.

Authors:  David J Berry; Rafael Torres Martin de Rosales; Putthiporn Charoenphun; Philip J Blower
Journal:  Mini Rev Med Chem       Date:  2012-10       Impact factor: 3.862

9.  Optimal timing for initial and redistribution technetium 99m-N-NOET image acquisition.

Authors:  F D Petruzella; M Ruiz; P Katsiyiannis; D D Watson; R Pasqualini; G A Beller; D K Glover
Journal:  J Nucl Cardiol       Date:  2000 Mar-Apr       Impact factor: 5.952

10.  Diagnostic accuracy of myocardial perfusion imaging with single photon emission computed tomography and positron emission tomography: a comparison with coronary angiography.

Authors:  Lars Husmann; Mischa Wiegand; Ines Valenta; Oliver Gaemperli; Tiziano Schepis; Patrick T Siegrist; Mehdi Namdar; Christophe A Wyss; Hatem Alkadhi; Philipp A Kaufmann
Journal:  Int J Cardiovasc Imaging       Date:  2007-12-25       Impact factor: 2.357

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.