Literature DB >> 7769437

Automated alignment and sizing of myocardial stress and rest scans to three-dimensional normal templates using an image registration algorithm.

P J Slomka1, G A Hurwitz, J Stephenson, T Cradduck.   

Abstract

UNLABELLED: To optimize the interpretation of myocardial SPECT, we developed an automated method for alignment, sizing and quantification of images using three-dimensional reference templates.
METHODS: Stress and rest reference templates were built using a hybrid three-dimensional image registration scheme based on principal-axes and simplex-minimization techniques. Normal patient studies were correlated to a common orientation, position and size. Aligned volumes were added to each other to create amalgamated templates. Separate templates were built for normal stress and rest SPECT 99mTc-sestamibi scans of 23 men and 15 women. The same algorithm was used to correlate abnormal test-patient studies with respective normal templates. The robustness of the fitting algorithm was evaluated by registering data with simulated defects and by repeated registrations after arbitrary misalignment of images. To quantify regional count distribution, 18 three-dimensional segments were outlined on the templates, and counts in the segment were evaluated for all test patients.
RESULTS: Our technique provided accurate and reproducible alignment of the images and compensated for varying dimensions of the myocardium by adjusting scaling parameters. The algorithm successfully registered both normal and abnormal studies. The mean registration errors caused by simulated defects were 1.5 mm for position, 1.3 degrees for tilt and 5.3% for sizing (stress images), and 1.4 mm, 2.0 degrees and 3.7% (rest images); these errors were below the limits of visual assessment.
CONCLUSION: Automated three-dimensional image fitting to normal templates can be used for reproducible quantification of myocardial SPECT, eliminating operator-dependence of the results.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7769437

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  22 in total

Review 1.  Advances in quantitative perfusion SPECT imaging.

Authors:  Edward P Ficaro; James R Corbett
Journal:  J Nucl Cardiol       Date:  2004 Jan-Feb       Impact factor: 5.952

2.  Detecting changes in serial myocardial perfusion SPECT: a simulation study.

Authors:  Tracy L Faber; Jan Modersitzki; Russell D Folks; Ernest V Garcia
Journal:  J Nucl Cardiol       Date:  2005 May-Jun       Impact factor: 5.952

3.  EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology.

Authors:  B Hesse; K Tägil; A Cuocolo; C Anagnostopoulos; M Bardiés; J Bax; F Bengel; E Busemann Sokole; G Davies; M Dondi; L Edenbrandt; P Franken; A Kjaer; J Knuuti; M Lassmann; M Ljungberg; C Marcassa; P Y Marie; F McKiddie; M O'Connor; E Prvulovich; R Underwood; B van Eck-Smit
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-07       Impact factor: 9.236

4.  Alignment of 3-dimensional cardiac structures in O-15-labeled water PET emission images with mutual information.

Authors:  Anu Juslin; Jyrki Lötjönen; Sergey V Nesterov; Kari Kalliokoski; Juhani Knuuti; Ulla Ruotsalainen
Journal:  J Nucl Cardiol       Date:  2007-01       Impact factor: 5.952

5.  Ventilation and perfusion lung scintigraphy of allergen-induced airway responses in atopic asthmatic subjects.

Authors:  Krishnan Parameswaran; Andrew C Knight; Niall P Keaney; E David Williams; Ian K Taylor
Journal:  Can Respir J       Date:  2007 Jul-Aug       Impact factor: 2.409

6.  On the generation of short-axis and radial long-axis slices in thallium-201 myocardial perfusion single-photon emission tomography.

Authors:  R P van Hastenberg; G J Kemerink; A Hasman
Journal:  Eur J Nucl Med       Date:  1996-08

7.  Brain mapping of median nerve somatosensory evoked potentials with combined 99mTc-ECD single-photon emission tomography and magnetic resonance imaging.

Authors:  U A Zifko; P J Slomka; G B Young; R H Reid; C F Bolton
Journal:  Eur J Nucl Med       Date:  1996-05

8.  A novel deep-learning-based approach for automatic reorientation of 3D cardiac SPECT images.

Authors:  Duo Zhang; P Hendrik Pretorius; Kaixian Lin; Weibing Miao; Jingsong Li; Michael A King; Wentao Zhu
Journal:  Eur J Nucl Med Mol Imaging       Date:  2021-04-02       Impact factor: 9.236

Review 9.  An automatic approach to the analysis, quantitation and review of perfusion and function from myocardial perfusion SPECT images.

Authors:  G Germano; P B Kavanagh; D S Berman
Journal:  Int J Card Imaging       Date:  1997-08

10.  Late gadolinium uptake demonstrated with magnetic resonance in patients where automated PERFIT analysis of myocardial SPECT suggests irreversible perfusion defect.

Authors:  Lene Rosendahl; Peter Blomstrand; Jan L Ohlsson; Per-Gunnar Björklund; Britt-Marie Ahlander; Sven-Ake Starck; Jan E Engvall
Journal:  BMC Med Imaging       Date:  2008-12-12       Impact factor: 1.930