Literature DB >> 7766980

Separation of fat and water in fast spin-echo MR imaging with the three-point Dixon technique.

P A Hardy1, R S Hinks, J A Tkach.   

Abstract

A method for suppressing fat in fast spin-echo imaging with the three-point Dixon technique is described. The method differs from the three-point Dixon method used in conventional spin-echo imaging in that the readout gradient instead of a radio-frequency pulse is shifted. This method preserves the Carr-Purcell-Meiboom-Gill nature of the fast spin-echo sequence and hence is less sensitive to magnetic field inhomogeneities and resonance frequency mistuning. As in the original three-point Dixon technique used in conventional spin-echo imaging, three acquisitions are required to estimate the field inhomogeneity and completely separate fat and water. The extra time required is not excessive considering that the fast spin-echo method is frequently applied with multiple signal acquisition. Also, this technique achieves an expected signal-to-noise ratio comparable to 2.67 signal acquisitions, which is approximately 94% of the signal-to-noise ratio obtained with three signal acquisitions. The method is demonstrated with applications to phantoms and a human volunteer.

Entities:  

Mesh:

Year:  1995        PMID: 7766980     DOI: 10.1002/jmri.1880050213

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  26 in total

1.  Fast three-point Dixon MR imaging of the retrobulbar space with low-resolution images for phase correction: comparison with fast spin-echo inversion recovery imaging.

Authors:  F J Rybicki; R V Mulkern; R L Robertson; C D Robson; T Chung; J Ma
Journal:  AJNR Am J Neuroradiol       Date:  2001-10       Impact factor: 3.825

2.  Post-processing water-fat imaging technique for fat suppression in a low-field MR imaging system, evaluation in patients with rheumatoid arthritis.

Authors:  Kari Palosaari; Osmo Tervonen
Journal:  MAGMA       Date:  2002-11       Impact factor: 2.310

3.  Use of the modified three-point Dixon technique in obtaining T1-weighted contrast-enhanced fat-saturated images on an open magnet.

Authors:  Rolf W Huegli; Phillip F J Tirman; Harald M Bonel; Harald Staedele; Souhil Zaim; Mikayel Grigorian; Harry K Genant
Journal:  Eur Radiol       Date:  2004-04-21       Impact factor: 5.315

4.  Fat signal suppression in head and neck imaging using fast spin-echo-IDEAL technique.

Authors:  A V Barger; D R DeLone; M A Bernstein; K M Welker
Journal:  AJNR Am J Neuroradiol       Date:  2006 Jun-Jul       Impact factor: 3.825

5.  Recovery of Damped Exponentials Using Structured Low Rank Matrix Completion.

Authors:  Arvind Balachandrasekaran; Vincent Magnotta; Mathews Jacob
Journal:  IEEE Trans Med Imaging       Date:  2017-07-14       Impact factor: 10.048

6.  Volumetric fat-water separated T2-weighted MRI.

Authors:  Shreyas S Vasanawala; Ananth J Madhuranthakam; Ramesh Venkatesan; Arvind Sonik; Peng Lai; Anja C S Brau
Journal:  Pediatr Radiol       Date:  2011-01-18

7.  Three-point Dixon method with a MISSTEC sequence.

Authors:  F Lethimonnier; F Franconi; S Akoka
Journal:  MAGMA       Date:  1997-12       Impact factor: 2.310

8.  A method for the automatic segmentation of brown adipose tissue.

Authors:  K N Bhanu Prakash; Hussein Srour; Sendhil S Velan; Kai-Hsiang Chuang
Journal:  MAGMA       Date:  2016-01-11       Impact factor: 2.310

9.  Comparison of fat-water MRI and single-voxel MRS in the assessment of hepatic and pancreatic fat fractions in humans.

Authors:  Houchun H Hu; Hee-Won Kim; Krishna S Nayak; Michael I Goran
Journal:  Obesity (Silver Spring)       Date:  2009-10-15       Impact factor: 5.002

10.  Reproducible MRI measurement of adipose tissue volumes in genetic and dietary rodent obesity models.

Authors:  David H Johnson; Chris A Flask; Paul R Ernsberger; Wilbur C K Wong; David L Wilson
Journal:  J Magn Reson Imaging       Date:  2008-10       Impact factor: 4.813

View more