Turbulent blood flow in the ascending aorta of humans with normal and diseased aortic valves.

P D Stein, H N Sabbah.   

Abstract

Turbulent blood flow may contribute to a variety of pathophysiological effects. Because of its postulated importance, this study was undertaken to determine whether turbulent flow does in fact occur in the human body. In 15 persons (seven normal, seven aortic valvular disease, one prosthetic aortic valve), point velocity was measured in the ascending aorta with a hot-film anemometer probe. In one normal individual with a high cardiac output, turbulent flow occurred above the aortic valve during peak flow which corresponded to a peak Reynolds number of 10,000. In the other six normal subjects (peak Reynolds numbers of 5,700-8,900), flow was highly disturbed during peak ejection. Each of the subjects with aortic valvular disease and the subject with a prosthetic aortic valve showed turbulent flow during nearly the entire period of ejection, with Fourier components of velocity of significant magnitude up to 320 Hz (the maximum frequency we could evaluate with the equipment available). The turbulence energy density was higher in subjects with abnormal valves (3.2-14.6 ergs/cm3), than in normal subjects (0.6-2.9 ergs/cm3). In subjects with aortic stenosis, turbulence was observed throughout the ascending aorta and in the innominate artery. In others, the turbulence dissipated more proximally. The results of this study indicate that turbulent flow can occur in the ascending aorta of subjects with normal cardiac function; and it occurs consistently in the ascending aorta of individuals with abnormal aortic valves.

Entities:  

Mesh:

Year:  1976        PMID: 776437     DOI: 10.1161/01.res.39.1.58

Source DB:  PubMed          Journal:  Circ Res        ISSN: 0009-7330            Impact factor:   17.367


  43 in total

1.  Raised interleukin 6 concentrations as a predictor of postangioplasty restenosis.

Authors:  T Suzuki; S Ishiwata; K Hasegawa; K Yamamoto; T Yamazaki
Journal:  Heart       Date:  2000-05       Impact factor: 5.994

2.  Plasma fibrinogen, soluble P-selectin, and von Willebrand factor in aortic valve disease: evidence for abnormal haemorheology, platelet activation, and endothelial dysfunction.

Authors:  I R Goldsmith; A D Blann; R L Patel; G Y Lip
Journal:  Heart       Date:  2000-05       Impact factor: 5.994

3.  In vitro hemodynamic investigation of the embryonic aortic arch at late gestation.

Authors:  Kerem Pekkan; Lakshmi P Dasi; Paymon Nourparvar; Srinivasu Yerneni; Kimimasa Tobita; Mark A Fogel; Bradley Keller; Ajit Yoganathan
Journal:  J Biomech       Date:  2008-05-07       Impact factor: 2.712

4.  Fluid-structure interaction modeling of calcific aortic valve disease using patient-specific three-dimensional calcification scans.

Authors:  Rotem Halevi; Ashraf Hamdan; Gil Marom; Karin Lavon; Sagit Ben-Zekry; Ehud Raanani; Danny Bluestein; Rami Haj-Ali
Journal:  Med Biol Eng Comput       Date:  2016-02-23       Impact factor: 2.602

5.  Time-frequency analysis of heart murmurs. Part I: Parametric modelling and numerical simulations.

Authors:  F Debiais; L G Durand; P Pibarot; R Guardo
Journal:  Med Biol Eng Comput       Date:  1997-09       Impact factor: 2.602

6.  Optimization of diameters and bifurcation angles in lung and vascular tree structures.

Authors:  H B Uylings
Journal:  Bull Math Biol       Date:  1977       Impact factor: 1.758

7.  Suitability of lattice Boltzmann inlet and outlet boundary conditions for simulating flow in image-derived vasculature.

Authors:  Bradley Feiger; Madhurima Vardhan; John Gounley; Matthew Mortensen; Priya Nair; Rafeed Chaudhury; David Frakes; Amanda Randles
Journal:  Int J Numer Method Biomed Eng       Date:  2019-04-01       Impact factor: 2.747

8.  Sinus of Valsalva: a converging nozzle that contributes to stable flow in the coronary arteries.

Authors:  Paul D Stein; Edward F Blick; Sarah Kim Shields; Fadi Matta
Journal:  J Anat       Date:  2014-05-17       Impact factor: 2.610

9.  Numerical study of turbulent blood flow through a caged-ball prosthetic heart valve using a boundary-fitted co-ordinate system.

Authors:  K Thalassoudis; J Mazumdar; B J Noye; I H Craig
Journal:  Med Biol Eng Comput       Date:  1987-03       Impact factor: 2.602

10.  Combined In Silico and In Vitro Approach Predicts Low Wall Shear Stress Regions in a Hemofilter that Correlate with Thrombus Formation In Vivo.

Authors:  Amanda K W Buck; Joseph J Groszek; Daniel C Colvin; Sara B Keller; Clark Kensinger; Rachel Forbes; Seth Karp; Phillip Williams; Shuvo Roy; William H Fissell
Journal:  ASAIO J       Date:  2018 Mar/Apr       Impact factor: 2.872