Interpretation of high-pass resolution perimetry with a probability plot.

S L Graham1, S M Drance.   

Abstract

BACKGROUND: The interpretation of high-pass resolution perimetry (HRP) fields can be difficult. An age-related probability plot was derived from a known data base to determine whether this improved specificity and sensitivity in early glaucoma detection.
METHODS: Forty glaucoma patients with minor field loss and 40 normals of equivalent age and sex underwent HRP. All had previous Humphrey field data available for comparison. The detection of previously confirmed field defects by HRP was examined using different parameters.
RESULTS: Using the age-corrected 95% confidence levels gave the best results, with sensitivity of 82.5% (33/40) and specificity of 85% (34/40). Using the contour plot yielded lower sensitivity (67.5%), while subjectively "eyeballing" the ring printout gave higher sensitivity (90%), but led to poor specificity (72.5%).
CONCLUSION: The use of a probability plot enhances the performance of HRP. A certain proportion of cases may be missed using one criterion alone, but combining the information with other indices can increase the yield.

Entities:  

Mesh:

Year:  1995        PMID: 7758981     DOI: 10.1007/BF00166606

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  12 in total

1.  Characteristics of the normal central visual field measured with resolution perimetry.

Authors:  P House; M Schulzer; S Drance; G Douglas
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1991       Impact factor: 3.117

2.  The effect of topical antiglaucoma drugs on the results of high-pass resolution perimetry.

Authors:  L M Martin-Boglind; A Graves; P Wanger
Journal:  Am J Ophthalmol       Date:  1991-06-15       Impact factor: 5.258

3.  Intratest variability in conventional and high-pass resolution perimetry.

Authors:  B C Chauhan; P H House
Journal:  Ophthalmology       Date:  1991-01       Impact factor: 12.079

4.  Evaluation of sensitivity and specificity of spatial resolution and Humphrey automated perimetry in pseudotumor cerebri patients and normal subjects.

Authors:  M Wall; M D Conway; P H House; R Allely
Journal:  Invest Ophthalmol Vis Sci       Date:  1991-12       Impact factor: 4.799

5.  Light-sense, flicker and resolution perimetry in glaucoma: a comparative study.

Authors:  B J Lachenmayr; S M Drance; G R Douglas; F S Mikelberg
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1991       Impact factor: 3.117

6.  Vanishing optotypes. New type of acuity test letters.

Authors:  L Frisén
Journal:  Arch Ophthalmol       Date:  1986-08

7.  Pattern-reversal electroretinograms and high-pass resolution perimetry in suspected or early glaucoma.

Authors:  P Wanger; H E Persson
Journal:  Ophthalmology       Date:  1987-09       Impact factor: 12.079

8.  High-pass resolution targets in peripheral vision.

Authors:  L Frisén
Journal:  Ophthalmology       Date:  1987-09       Impact factor: 12.079

9.  [Studies on the distribution and number of retinal ganglion cells in the human].

Authors:  O Oppel
Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol       Date:  1967

10.  Diffuse and localized glaucomatous field loss in light-sense, flicker and resolution perimetry.

Authors:  B J Lachenmayr; S M Drance; B C Chauhan; P H House; S Lalani
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1991       Impact factor: 3.117

View more
  1 in total

1.  Probing glaucoma visual damage by rarebit perimetry.

Authors:  P Brusini; M L Salvetat; L Parisi; M Zeppieri
Journal:  Br J Ophthalmol       Date:  2005-02       Impact factor: 4.638

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.