Literature DB >> 1748561

Evaluation of sensitivity and specificity of spatial resolution and Humphrey automated perimetry in pseudotumor cerebri patients and normal subjects.

M Wall1, M D Conway, P H House, R Allely.   

Abstract

To determine the sensitivity and specificity of high-pass resolution perimetry ("ring test"), 18 patients with pseudotumor cerebri (PTC) and 18 age-matched controls were examined with the Humphrey program 24-2 and the ring test. Goldmann perimetry also was done to determine if defects found with the ring test were present with another method. Testing with Humphrey perimetry revealed defects in 15 PTC patients and four control subjects; with the ring test, 13 PTC patients and two control subjects had abnormalities. The disturbed areas in the control subjects with both automated tests were not reproducible. Humphrey perimetry had a sensitivity of 83% and the ring test, 72%. The specificities were Humphrey perimetry, 78% and the ring test, 89%. These differences were not statistically significant. Qualitative assessment of the presence and extent of damage using the pointwise probability plots and graphically displayed raw data showed good correlation of the tests in 11 of the 18 patients. The lack of correlation in four of the patients was caused by the presence of a generalized depression or a peripheral contraction on the Humphrey test; this defect, not present on retesting, may have been related to fatigue or poor motivation. The ring test is a sensitive and specific perimetric technique in patients with PTC.

Entities:  

Mesh:

Year:  1991        PMID: 1748561

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  5 in total

1.  Interpretation of high-pass resolution perimetry with a probability plot.

Authors:  S L Graham; S M Drance
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1995-03       Impact factor: 3.117

Review 2.  High-pass resolution perimetry. A clinical review.

Authors:  L Frisén
Journal:  Doc Ophthalmol       Date:  1993       Impact factor: 2.379

3.  Psychophysical testing in glaucoma.

Authors:  K Hitchings
Journal:  Br J Ophthalmol       Date:  1993-08       Impact factor: 4.638

4.  Optic nerve diameters and perimetric thresholds in idiopathic intracranial hypertension.

Authors:  T Salgarello; C Tamburrelli; B Falsini; A Giudiceandrea; A Colotto
Journal:  Br J Ophthalmol       Date:  1996-06       Impact factor: 4.638

5.  Eye-tracking-based visual field analysis (EFA): a reliable and precise perimetric methodology for the assessment of visual field defects.

Authors:  Michael Christian Leitner; Florian Hutzler; Sarah Schuster; Lorenzo Vignali; Patrick Marvan; H A Reitsamer; Stefan Hawelka
Journal:  BMJ Open Ophthalmol       Date:  2021-03-17
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.