Non-invasive monitoring of effective dialysis dose delivered to the haemodialysis patient.

T Petitclerc1, B Béné, C Jacobs, M C Jaudon, N Goux.   

Abstract

Assessment of normalized dialysis dose Kt/V actually delivered to the patient carries the drawback of requiring several blood or dialysate samplings and urea concentration measurements. In order to easily quantify Kt/V, we validate here the routine implementation of an original technique for the non-invasive, on-line, and fully automatic estimation of total mean urea clearance. This estimation is obtained from the measurement by a conductivity method of the effective ionic dialysance DR, which is the dialysance of electrolytes taking into account ultrafiltration and recirculation. The observed increase in DR with ultrafiltration rate and decrease in DR with elevation of access recirculation ratio show that the estimation of DR is affected by ultrafiltration and recirculation in a consistent manner. The mean value Keff of ionic dialysance DR was compared with the value Kdc of effective urea clearance obtained by dialysate collection during 12 haemodialysis sessions. The similarity (magnitude of variation 5%) between the ionic dialysance Keff and the effective urea clearance Kdc supports the validity of the equivalence between the transfer characteristics of electrolytes and urea through the dialyser membrane. Given an estimate of the urea distribution volume V, this estimation of effective urea clearance by ionic dialysance measurement allows an on-line estimation of the normalized dialysis dose Kt/V actually delivered to the patient.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7753455

Source DB:  PubMed          Journal:  Nephrol Dial Transplant        ISSN: 0931-0509            Impact factor:   5.992


  5 in total

1.  Efficacy of dialysis in peritoneal dialysis: utility of bioimpedance to calculate Kt/V and the search for a target Kt.

Authors:  G Martínez Fernández; A Ortega Cerrato; J Masiá Mondéjar; A Pérez Rodríguez; F Llamas Fuentes; C Gómez Roldán; Juan Pérez-Martínez
Journal:  Clin Exp Nephrol       Date:  2012-08-11       Impact factor: 2.801

2.  Evaluation of hemodialysis adequacy using online Kt/V and single-pool variable-volume urea Kt/V.

Authors:  Alicja E Grzegorzewska; Wojciech Banachowicz
Journal:  Int Urol Nephrol       Date:  2008-07-01       Impact factor: 2.370

3.  Online conductivity monitoring of dialysis adequacy versus Kt/V derived from urea reduction ratio: A prospective study from a Saudi center.

Authors:  Khalid Al Saran; Alaa Sabry; Mamdouh Abdulghafour; Ahmed Yehia
Journal:  Int J Nephrol Renovasc Dis       Date:  2009-10-09

4.  Sodium concentration measurement during hemodialysis through ion-exchange resin and conductivity measure approach: in vitro experiments.

Authors:  Andrea Tura; Stefano Sbrignadello; Emanuele Mambelli; Paolo Ravazzani; Antonio Santoro; Giovanni Pacini
Journal:  PLoS One       Date:  2013-07-02       Impact factor: 3.240

5.  Correlation between Dt/V derived from ionic dialysance and blood-driven Kt/V of urea in African-American hemodialysis patients, based on body weight and ultrafiltration volume.

Authors:  Wihib Gebregeorgis; Zeenat Yousuf Bhat; Nishigandha Pradhan; Stephen D Migdal; Lakshminarayanan Nandagopal; Reddy Singasani; Tehmina Mushtaq; Ronald Thomas; Yahya M Osman Malik
Journal:  Clin Kidney J       Date:  2018-01-31
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.