Literature DB >> 7748114

The use of fractal analysis to reveal remodelling in human alveolar bone following the placement of dental implants.

R J Wilding1, J C Slabbert, H Kathree, C P Owen, K Crombie, P Delport.   

Abstract

In order to confirm the presence of adequate bone support for implants it is necessary to examine the surrounding bone at intervals. While this may be attempted by looking for changes in serial radiographs, such comparisons are inaccurate unless standardized procedures are followed which allow subtraction of consecutive digital images. As image textures are less susceptible to magnification distortion, it was decided to examine the fractal dimensions of successive radiographs of bone after implant placement. All available panoramic radiographs for each of 18 patients who had received fixed implant-supported prostheses were digitized. A window of bone adjacent and distal to the most posterior implant was defined as the region of interest; the fractal dimension of the image was calculated. Linear regression was used to investigate whether there were any significant shifts in fractal dimension during the recall period after implantation. A significant increase in fractal dimension was found during the period up to 2 yr after implantation (p < 0.001). The most pronounced increase was in the region of bone around the neck of the implant. An increase in orientation of the image in a direction oblique to the implant was also found during the same period. These changes are consistent with models derived from finite-element analysis that predict the relation between trabecular architecture and strain. One subject's radiographs had a significant negative regression slope, which further monitoring may reveal was an early sign of implant failure. The satisfactory remodelling of bone in response to implant placement may be monitored using a texture analysis of routine orthopantomograms.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7748114     DOI: 10.1016/0003-9969(94)00138-2

Source DB:  PubMed          Journal:  Arch Oral Biol        ISSN: 0003-9969            Impact factor:   2.633


  14 in total

1.  Image resolution and exposure time of digital radiographs affects fractal dimension of periapical bone.

Authors:  B Güniz Baksi; Aleš Fidler
Journal:  Clin Oral Investig       Date:  2011-11-29       Impact factor: 3.573

2.  Fractal analysis for the assessment of trabecular peri-implant alveolar bone using panoramic radiographs.

Authors:  Mert Zeytinoğlu; Betül İlhan; Nesrin Dündar; Hayal Boyacioğlu
Journal:  Clin Oral Investig       Date:  2014-05-07       Impact factor: 3.573

3.  Evaluation of the mandibular trabecular bone in patients with bruxism using fractal analysis.

Authors:  Melike Gulec; Melek Tassoker; Sevgi Ozcan; Kaan Orhan
Journal:  Oral Radiol       Date:  2020-01-13       Impact factor: 1.852

4.  Changes in the fractal dimension of peri-implant trabecular bone after loading: a retrospective study.

Authors:  Teh-Jing Mu; Dong-Won Lee; Kwang-Ho Park; Ik-Sang Moon
Journal:  J Periodontal Implant Sci       Date:  2013-10-29       Impact factor: 2.614

5.  The impact of Platelet Rich Plasma (PRP) in osseointegration of oral implants in dental panoramic radiography: texture based evaluation.

Authors:  Ioannis Georgakopoulos; Stavros Tsantis; Panagiotis Georgakopoulos; Panagiotis Korfiatis; Elena Fanti; Marialaura Martelli; Lena Costaridou; Theodoros Petsas; George Panayiotakis; Francesco Saverio Martelli
Journal:  Clin Cases Miner Bone Metab       Date:  2014-01

6.  Use of fractal analysis in dental images: a systematic review.

Authors:  Camila Nao Kato; Sâmila G Barra; Núbia Pk Tavares; Tânia Mp Amaral; Cláudia B Brasileiro; Ricardo A Mesquita; Lucas G Abreu
Journal:  Dentomaxillofac Radiol       Date:  2019-08-20       Impact factor: 2.419

7.  Fractal analysis of mandibular trabecular bone: optimal tile sizes for the tile counting method.

Authors:  Kyung-Hoe Huh; Jee-Seon Baik; Won-Jin Yi; Min-Suk Heo; Sam-Sun Lee; Soon-Chul Choi; Sun-Bok Lee; Seung-Pyo Lee
Journal:  Imaging Sci Dent       Date:  2011-06-23

8.  Effect of Image Resolution and Compression on Fractal Analysis of the Periapical Bone.

Authors:  Shiva Toghyani; Ibrahim Nasseh; Georges Aoun; Marcel Noujeim
Journal:  Acta Inform Med       Date:  2019-09

9.  Comparison of cone-beam computed tomography and digital panoramic radiography for detecting peri-implant alveolar bone changes using trabecular micro-structure analysis.

Authors:  Guldane Magat; Elif Oncu; Sevgi Ozcan; Kaan Orhan
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2022-02-28

10.  A clinical study of alveolar bone quality using the fractal dimension and the implant stability quotient.

Authors:  Dae-Hyun Lee; Young Ku; In-Chul Rhyu; Jeong-Ug Hong; Cheol-Woo Lee; Min-Suk Heo; Kyung-Hoe Huh
Journal:  J Periodontal Implant Sci       Date:  2010-02-28       Impact factor: 2.614

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.