Literature DB >> 7747577

Anterior chamber depth after posterior chamber intraocular lens implantation.

M Arai1, I Ohzuno, M Zako.   

Abstract

The precise behavior of the anterior chamber depth after intraocular lens implantation is uncertain. To ascertain variations in the values at different time points, we measured the anterior chamber depth in 38 eyes that had undergone extracapsular cataract extraction and posterior chamber intraocular lens implantation. Measurements were performed by ultrasonography preoperatively and at 2 days, 1 and 2 weeks postoperatively, and at 1-month intervals thereafter up to 10 months (mean follow-up period, 9 months). Results showed that two peaks of the anterior chamber depth occurred at 1 week and 3 months postoperatively (means +/- SD, 3.54 +/- 0.39 and 3.59 +/- 0.43 mm, respectively). A significant difference was found between the values measured preoperatively (3.29 +/- 0.57) and at 2 days postoperatively (3.33 +/- 0.39) and the 1-week postoperative value (p < 0.05, using the one-way analysis of variance test). A significant difference also was found between the preoperative and the monthly measurements and the 3-month postoperative measurement (p < 0.05). We also calculated the refractive error and found that during the second postoperative week, the refraction tended toward higher myopia that became more hyperopic 3 months postoperatively. This anterior chamber depth variation may cause variations in vision after cataract surgery with intraocular lens implantation.

Entities:  

Mesh:

Year:  1994        PMID: 7747577     DOI: 10.1111/j.1755-3768.1994.tb04682.x

Source DB:  PubMed          Journal:  Acta Ophthalmol (Copenh)        ISSN: 0001-639X


  6 in total

1.  A novel index for predicting intraocular pressure reduction following cataract surgery.

Authors:  S A Issa; J Pacheco; U Mahmood; J Nolan; S Beatty
Journal:  Br J Ophthalmol       Date:  2005-05       Impact factor: 4.638

2.  [Analysis of optical parameters after cataract surgery and implantation of foldable lens].

Authors:  B Falkenberg; A Kutschan; W Wiegand
Journal:  Ophthalmologe       Date:  2005-06       Impact factor: 1.059

3.  Anterior chamber depth measured by two methods in myopic and hyperopic phakic IOL implant.

Authors:  M Vetrugno; N Cardascia; L Cardia
Journal:  Br J Ophthalmol       Date:  2000-10       Impact factor: 4.638

4.  Influences of anterior capsule polishing on effective lens position after cataract surgery: a randomized controlled trial.

Authors:  Yang Gao; Guang-Fu Dang; Xu Wang; Lian Duan; Xin-Yi Wu
Journal:  Int J Clin Exp Med       Date:  2015-08-15

5.  Evaluation of Anterior Segment Parameter Changes Using the Sirius after Uneventful Phacoemulsification.

Authors:  Ali Şimşek; Burak Bilgin; Musa Çapkın; Şemsettin Bilak; Mete Güler; Ali Hakim Reyhan
Journal:  Korean J Ophthalmol       Date:  2016-07-21

6.  Topical vs Peribulbar Anesthesia: Comparison of Anterior Chamber Depth and the Resultant Visual Outcome After Phacoemulsification.

Authors:  Mayuresh P Naik; Harinder Singh Sethi; Amita Yadav
Journal:  Clin Ophthalmol       Date:  2020-11-03
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.