Literature DB >> 7744725

Possible interference of lactose-fermenting marine vibrios in coliform beta-D-galactosidase assays.

C M Davies1, S C Apte, S M Peterson.   

Abstract

An investigation into possible interferences in beta-D-galactosidase-based assays for coliform bacteria in marine waters was carried out. A rapid instrumental fluorescence assay for beta-D-galactosidase activity, using 4-methylumbelliferyl-beta-D-galactoside as a substrate, was used to investigate activities of this enzyme in non-coliform bacterial isolates from coastal waters. Only 2% of isolates showed slight enzyme activity after a 1-h incubation period at 44.5 degrees C. At a lower incubation temperature of 20 degrees C, 51% and 94% of the isolates showed some enzyme activity within 6 h and 48 h, respectively. Fifty-nine out of 67 of these isolates were identified as Vibrio species. A lac+ strain of Vibrio vulnificus was found to produce beta-D-galactosidase which caused significant false-positive reactions in the Colilert-Marine Water assay when present at concentrations of 10 cfu ml-1 or greater. This interference could be overcome by addition of the vibriostatic agent O/129. The high fluorescence of this reagent, however, precluded the simultaneous determination of Escherichia coli in the Colilert test and also its use in instrumental fluorescence assays. It was concluded that in assays employing high temperatures and short incubation times, Vibrio species are unlikely to cause significant interferences.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7744725     DOI: 10.1111/j.1365-2672.1995.tb03423.x

Source DB:  PubMed          Journal:  J Appl Bacteriol        ISSN: 0021-8847


  5 in total

1.  Field evaluation of a semiautomated method for rapid and simple analysis of recreational water microbiological quality.

Authors:  M B Anglès d'Auriac; H Roberts; T Shaw; R Sirevåg; L F Hermansen; J D Berg
Journal:  Appl Environ Microbiol       Date:  2000-10       Impact factor: 4.792

2.  Comparison and verification of bacterial water quality indicator measurement methods using ambient coastal water samples.

Authors:  John F Griffith; Larissa A Aumand; Ioannice M Lee; Charles D McGee; Laila L Othman; Kerry J Ritter; Kathy O Walker; Stephen B Weisberg
Journal:  Environ Monit Assess       Date:  2006-05       Impact factor: 2.513

3.  Marine bacteria cause false-positive results in the Colilert-18 rapid identification test for Escherichia coli in Florida waters.

Authors:  John M Pisciotta; Damon F Rath; Paul A Stanek; D Michael Flanery; Valerie J Harwood
Journal:  Appl Environ Microbiol       Date:  2002-02       Impact factor: 4.792

4.  Enzyme characteristics of beta-D-galactosidase- and beta-D-glucuronidase-positive bacteria and their interference in rapid methods for detection of waterborne coliforms and Escherichia coli.

Authors:  I Tryland; L Fiksdal
Journal:  Appl Environ Microbiol       Date:  1998-03       Impact factor: 4.792

5.  Comparison of membrane filtration and multiple-tube fermentation by the colilert and enterolert methods for detection of waterborne coliform bacteria, Escherichia coli, and enterococci used in drinking and bathing water quality monitoring in southern sweden.

Authors:  K F Eckner
Journal:  Appl Environ Microbiol       Date:  1998-08       Impact factor: 4.792

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.