Literature DB >> 7744177

Time constant/volume relationship of passive expiration in mechanically ventilated ARDS patients.

J Guttmann1, L Eberhard, B Fabry, W Bertschmann, J Zeravik, M Adolph, J Eckart, G Wolff.   

Abstract

Since the adult respiratory distress syndrome (ARDS) lung is known to be inhomogeneous, one could expect an uneven distribution of expiratory time constant during uninterrupted mechanical ventilation. We investigated the time constant/volume relationship of passive expiration, and their modification by external resistive elements. In 12 paralysed intubated ARDS patients, we determined the expiratory time constant (tau E) as a function of the expired volume (VE) during uninterrupted mechanical ventilation. Mean expiratory time was 2.9 +/- 0.3 s (+/- SD). VE was divided into five equal volume slices (portions) and a mean tau E calculated from the expiratory tidal volume/flow curve for each slice. The mean values of tau E for each volume slice did not differ significantly throughout expiration, averaging 690 +/- 218 ms (mean +/- SD of five slices and 12 patients). We show that the flow-dependent resistance of the endotracheal tube (RETT) is mainly responsible for the observed time constant homogeneity. We conclude that in ARDS patients during uninterrupted mechanical ventilation the time constants of passive expiration are markedly modified by the flow-dependent resistance of the endotracheal tube (RETT), and also by the external resistance of tubing and ventilator (REX). RETT and REX render tau E about three times larger than the time constant of the patient's respiratory system alone.

Entities:  

Mesh:

Year:  1995        PMID: 7744177     DOI: 10.1183/09031936.95.08010114

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  13 in total

1.  Estimation of expiratory time constants via fuzzy clustering.

Authors:  Marlies S Lourens; Lejla Ali; Bart van den Berg; Anton F M Verbraak; Jan M Bogaard; Henk C Hoogsteden; Robert Babuska
Journal:  J Clin Monit Comput       Date:  2002-01       Impact factor: 2.502

2.  Respiratory comfort of automatic tube compensation and inspiratory pressure support in conscious humans.

Authors:  J Guttmann; H Bernhard; G Mols; A Benzing; P Hofmann; C Haberthür; D Zappe; B Fabry; K Geiger
Journal:  Intensive Care Med       Date:  1997-11       Impact factor: 17.440

3.  Pattern of lung emptying and expiratory resistance in mechanically ventilated patients with chronic obstructive pulmonary disease.

Authors:  Eumorfia Kondili; Christina Alexopoulou; George Prinianakis; Nectaria Xirouchaki; Dimitris Georgopoulos
Journal:  Intensive Care Med       Date:  2004-03-31       Impact factor: 17.440

4.  Expiratory Time Constant and Sleep Apnea Severity in the Overlap Syndrome.

Authors:  Darunee Wiriyaporn; Lu Wang; Loutfi S Aboussouan
Journal:  J Clin Sleep Med       Date:  2016-03       Impact factor: 4.062

5.  Analysis of forced expired volume signals using multi-exponential functions.

Authors:  H Steltner; M Vogel; S Sorichter; H Matthys; J Guttmann; J Timmer
Journal:  Med Biol Eng Comput       Date:  2001-03       Impact factor: 3.079

6.  The role of high airway pressure and dynamic strain on ventilator-induced lung injury in a heterogeneous acute lung injury model.

Authors:  Sumeet V Jain; Michaela Kollisch-Singule; Joshua Satalin; Quinn Searles; Luke Dombert; Osama Abdel-Razek; Natesh Yepuri; Antony Leonard; Angelika Gruessner; Penny Andrews; Fabeha Fazal; Qinghe Meng; Guirong Wang; Louis A Gatto; Nader M Habashi; Gary F Nieman
Journal:  Intensive Care Med Exp       Date:  2017-05-12

7.  Regional expiratory time constants in severe respiratory failure estimated by electrical impedance tomography: a feasibility study.

Authors:  Christian Karagiannidis; Andreas D Waldmann; Péter L Róka; Tina Schreiber; Stephan Strassmann; Wolfram Windisch; Stephan H Böhm
Journal:  Crit Care       Date:  2018-09-21       Impact factor: 9.097

8.  Expiratory automatic endotracheal tube compensation reduces dynamic hyperinflation in a physical lung model.

Authors:  Christoph Haberthür; Annekathrin Mehlig; John F Stover; Stefan Schumann; Knut Möller; Hans-Joachim Priebe; Josef Guttmann
Journal:  Crit Care       Date:  2009-01-23       Impact factor: 9.097

9.  Expiratory time constant for determinations of plateau pressure, respiratory system compliance, and total resistance.

Authors:  Nawar Al-Rawas; Michael J Banner; Neil R Euliano; Carl G Tams; Jeff Brown; A Daniel Martin; Andrea Gabrielli
Journal:  Crit Care       Date:  2013-02-05       Impact factor: 9.097

10.  Effect of tidal volume and positive end-expiratory pressure on expiratory time constants in experimental lung injury.

Authors:  William R Henderson; Paolo B Dominelli; Yannick Molgat-Seon; Rachel Lipson; Donald E G Griesdale; Mypinder Sekhon; Najib Ayas; A William Sheel
Journal:  Physiol Rep       Date:  2016-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.