Cardiac output in single-lead VDD pacing versus rate-matched VVIR pacing.

B Nowak1, T Voigtländer, E Himmrich, A Liebrich, G Poschmann, S Epperlein, N Treese, J Meyer.   

Abstract

The importance of atrioventricular synchronous pacing compared with single-chamber rate-responsive pacing is still under discussion, especially for low-intensity workload representing daily life activities. We evaluated hemodynamics in single-lead VDD pacing versus VVIR pacing in 11 patients (8 men and 3 women, aged 58.6 +/- 13.8 years) with normal left ventricular function and a previously implanted single-lead VDDR pacemaker. A low-intensity steady-state treadmill test at 1 to 2.5 mph with a gradient of 2% to 4% was performed. Cardiac output was determined using a standard carbon dioxide rebreathing technique. Initially, the VDD mode was programmed, and after 5 minutes of exercise, cardiac output was measured in steady-state conditions. The pacemaker was then reprogrammed to the VVI mode at a rate 5 to 10 beats above the maximal atrial tracking rate to simulate rate-matched VVIR pacing (VVIRm). After 5 additional minutes of steady-state exercise, cardiac output was measured again. The maximal atrial rate in the VDD mode was 119 +/- 19 beats/min versus a programmed rate of 129 +/- 18 beats/min in the VVIRm mode. VDD pacing resulted in a significantly higher cardiac output than VVIRm pacing (10.6 +/- 1.9 vs 9.2 +/- 1.4 L/min; p < 0.002), with a mean difference of 1.6 +/- 1.2 L/min between the 2 modes. In the VDD mode, stroke volume (90.7 +/- 20.1 vs 71.6 +/- 13.0 ml; p < 0.001) and maximal oxygen uptake (1,183 +/- 264 vs 1,076 +/- 289 ml/min, p < 0.01) were also higher than in VVIRm.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1995        PMID: 7732998     DOI: 10.1016/s0002-9149(99)80684-5

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  4 in total

1.  [Atrial sensing with fixed and floating electrodes at identical activities].

Authors:  D Hartung; L Thiele; W M Hartung
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2009-04-18

2.  Predictors of loss of atrioventricular synchrony in single lead VDD pacing.

Authors:  P Hunziker; P Buser; M Pfisterer; F Burkart; S Osswald
Journal:  Heart       Date:  1998-10       Impact factor: 5.994

3.  Long-term outcome of atrial synchronous mode pacing in patients with atrioventricular block using a single lead.

Authors:  Miry Blich; Mahmoud Suleiman; Tawfiq Zeidan Shwiri; Ibrahim Marai; Monther Boulos; Shlomo Amikam
Journal:  Clin Cardiol       Date:  2010-01       Impact factor: 2.882

Review 4.  Dual chamber versus single chamber ventricular pacemakers for sick sinus syndrome and atrioventricular block.

Authors:  J Dretzke; W D Toff; G Y H Lip; J Raftery; A Fry-Smith; R Taylor
Journal:  Cochrane Database Syst Rev       Date:  2004
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.