In vivo comparison of different quantitative edge detection systems used for measuring coronary arterial diameters.

W Desmet1, I De Scheerder, K Beatt, T Huehns, J Piessens.   

Abstract

Three different systems for quantitative coronary analysis [Cardiovascular Measurement System (CMS); Polytron 1000; Angiographic Workstation (AWOS)] were compared in 109 patients before and after coronary angioplasty and at follow-up coronary angiography. Correlation coefficients were low and 95% limits of agreement were wide. In general, CMS exhibited a tendency to yield lower values for very small diameters and higher values for larger vessels. The acute gain in minimal luminal diameter was considerably smaller when assessed by AWOS as compared to Polytron (0.52 vs. 0.71 mm, P < .0001) and to CMS (0.52 vs. 0.75 mm, P < .0001). Long-term gain was much larger when assessed by Polytron as compared to AWOS (18.8 vs. 11.5%, P < .001) and it was almost double for CMS as compared to AWOS (20.7 vs. 11.5%, P < .0001). In conclusion, in the individual patient very different results can be obtained when different QCA systems are used, and systematic differences between the systems are encountered.

Entities:  

Mesh:

Year:  1995        PMID: 7728860     DOI: 10.1002/ccd.1810340319

Source DB:  PubMed          Journal:  Cathet Cardiovasc Diagn        ISSN: 0098-6569


  6 in total

1.  Validation of an accurate method for three-dimensional reconstruction and quantitative assessment of volumes, lengths and diameters of coronary vascular branches and segments from biplane angiographic projections.

Authors:  E Wellnhofer; A Wahle; I Mugaragu; J Gross; H Oswald; E Fleck
Journal:  Int J Card Imaging       Date:  1999-10

2.  The 6sigma quality approach for quantitative arteriography performance improvement.

Authors:  Jean Liénard; Francisco Sureda; Gérard Finet
Journal:  Int J Cardiovasc Imaging       Date:  2002-04       Impact factor: 2.357

3.  Comparison of QCA systems.

Authors:  U Dietz; H J Rupprecht; R Brennecke; H P Fritsch; J Woltmann; S Blankenberg; J Meyer
Journal:  Int J Card Imaging       Date:  1997-08

4.  Two-by-two cross-over study to evaluate agreement between versions of a quantitative coronary analysis system (QAngio XA).

Authors:  Kayoko Kozuma; Kosuke Kashiwabara; Tomohiro Shinozaki; Ken Kozuma; Koji Oba; Yutaka Matsuyama
Journal:  Int J Cardiovasc Imaging       Date:  2017-01-21       Impact factor: 2.357

5.  Inter- and intra-core laboratory variability in the quantitative coronary angiography analysis for drug-eluting stent treatment and follow up.

Authors:  Shigenori Ito; Kanako Kinoshita; Akiko Endo; Ryoko Kami; Yuko Kotake; Masato Nakamura
Journal:  Ther Adv Cardiovasc Dis       Date:  2020 Jan-Dec

6.  Long term effects of nisoldipine on the progression of coronary atherosclerosis and the occurrence of clinical events: the NICOLE study.

Authors:  J A Dens; W J Desmet; P Coussement; I K De Scheerder; K Kostopoulos; P Kerdsinchai; C Supanantaroek; J H Piessens
Journal:  Heart       Date:  2003-08       Impact factor: 5.994