Literature DB >> 7726464

Frictional resistances using Teflon-coated ligatures with various bracket-archwire combinations.

D J De Franco1, R E Spiller, J A von Fraunhofer.   

Abstract

Static frictional resistances were compared between Teflon-coated stainless steel and clear elastomeric ligatures used with various combinations of brackets and archwires. Stainless steel metal, polycrystalline ceramic and single crystal ceramic 0.022-inch slot brackets were used in combination with stainless steel and nickel titanium archwires, 0.018 inch and 0.016 x 0.022 inch. Friction was measured in the dry state at bracket-archwire angulations of 0, 5, 10, and 15 degrees. Moments induced by engagement of the archwires into the brackets were measured for each archwire type and bracket-archwire angulation. Teflon-coated ligatures produced less friction than elastomers for all bracket-archwire combinations. The ceramic brackets generally elicited greater frictional resistances than stainless steel brackets. Regarding both friction and control of tooth movement, these data suggest that sliding mechanics are best executed with stainless steel brackets and stainless steel archwires. Moreover, these data reveal the usefulness of Teflon-coated ligatures in minimizing the high friction of ceramic brackets when an esthetic appliance is imperative.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7726464     DOI: 10.1043/0003-3219(1995)065<0063:FRUTLW>2.0.CO;2

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  19 in total

1.  Frictional characteristics of composite orthodontic archwires against stainless steel and ceramic brackets in the passive and active configurations.

Authors:  S W Zufall; K C Kennedy; R P Kusy
Journal:  J Mater Sci Mater Med       Date:  1998-11       Impact factor: 3.896

2.  Plaque retention on elastomeric ligatures. An in vivo study.

Authors:  R Condò; A Casaglia; S G Condò; L Cerroni
Journal:  Oral Implantol (Rome)       Date:  2013-03-19

3.  Prophylaxis protocols and their impact on bracket friction force.

Authors:  Sérgio Elias Neves Cury; Silvio Augusto Bellini-Pereira; Aron Aliaga-Del Castillo; Sérgio Schneider; Arnaldo Pinzan; Guilherme Janson
Journal:  Angle Orthod       Date:  2019-07-15       Impact factor: 2.079

4.  Friction between Archwire of Different Sizes, Cross Section, Alloy and Brackets Ligated with Different Brands of Low Friction Elastic Ligatures- An Invitro Study.

Authors:  Bhushan Patil; Neeraj Suresh Patil; Veerendra Virupaxappa Kerudi; Shrikant Shrinivas Chitko; Amit Ratanlal Maheshwari; Harshal Ashok Patil; Nikhita Popatrao Pekhale; Pawankumar Dnyandeo Tekale
Journal:  J Clin Diagn Res       Date:  2016-04-01

5.  Mechanical properties of orthodontic wires covered with a polyether ether ketone tube.

Authors:  Nobukazu Shirakawa; Toshio Iwata; Shinjiro Miyake; Takero Otuka; So Koizumi; Toshitugu Kawata
Journal:  Angle Orthod       Date:  2018-03-21       Impact factor: 2.079

6.  Mechanical properties and surface characterization of translucent composite wire following topical fluoride treatment.

Authors:  Shaza M Hammad; Essam E Al-Wakeel; El-Sayed Gad
Journal:  Angle Orthod       Date:  2011-06-30       Impact factor: 2.079

7.  Effects of different ligature materials on friction in sliding mechanics.

Authors:  Aparna Khamatkar; Sushma Sonawane; Sameer Narkhade; Nitin Gadhiya; Abhijit Bagade; Vivek Soni; Asha Betigiri
Journal:  J Int Oral Health       Date:  2015-05

8.  In vitro evaluation of frictional forces of two ceramic orthodontic brackets versus a stainless steel bracket in combination with two types of archwires.

Authors:  Valiollah Arash; Mahmoud Rabiee; Vahid Rakhshan; Sara Khorasani; Farhad Sobouti
Journal:  J Orthod Sci       Date:  2015 Apr-Jun

9.  The comparison of frictional resistance in titanium, self-ligating stainless steel, and stainless steel brackets using stainless steel and TMA archwires: An in vitro study.

Authors:  Syed Altaf Khalid; Vadivel Kumar; Prithviraj Jayaram
Journal:  J Pharm Bioallied Sci       Date:  2012-08

10.  Effectiveness of medical coating materials in decreasing friction between orthodontic brackets and archwires.

Authors:  Nursel Arici; Berat S Akdeniz; Abdullah A Oz; Yucel Gencer; Mehmet Tarakci; Selim Arici
Journal:  Korean J Orthod       Date:  2021-07-25       Impact factor: 1.372

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.