Literature DB >> 7726246

Strategies to respond to polymerase chain reaction deoxyribonucleic acid amplification failure in a preimplantation genetic diagnosis program.

W E Gibbons1, S A Gitlin, S E Lanzendorf.   

Abstract

OBJECTIVES: Our purpose was to identify and evaluate practical methods within a preimplantation genetic diagnosis program that will increase the percentage of embryos for which a genetic diagnosis can be obtained, including clinical responses after failure of deoxyribonucleic acid amplification has occurred. STUDY
DESIGN: Known human lymphoblast cell lines and human embryo blastomeres were evaluated in a single-cell, nested primer polymerase chain reaction system with primer sequences for the specific locus surrounding the four base pair insertion mutation on exon 11 of beta-hexosaminidase A-Tay-Sachs disease, the delta F508 mutation of cystic fibrosis, and the sex-determining region on the Y chromosome. Reamplification polymerase chain reaction with standard polymerase chain reaction and primer extension preamplification was performed in deoxyribonucleic acid preparations after previous polymerase chain reaction amplification attempts had resulted in failure of amplification.
RESULTS: The amplification efficiency of Tay-Sachs disease, 51% (97/187), was significantly lower than that for cystic fibrosis, 85% (87/107), and for the sex-determining region on the Y chromosome, 85% (77/90). Tay-Sachs disease polymerase chain reaction amplification occurred in 51% of one-cell lymphoblasts, 89% of two-cell lymphoblasts, and 94% of samples when more than two cells were processed together. When previous amplification failure had occurred, standard Tay-Sachs disease polymerase chain reaction resulted in an amplification efficiency of 16% (three of 19), whereas primer extension preamplification polymerase chain reaction for Tay-Sachs disease resulted in amplification of 52% (31/59) lymphoblasts and 54% (13/24) of polyspermic human blastomeres. Four of six human blastomeres in which amplification failure occurred in a Tay-Sachs disease preimplantation genetic diagnosis cycle amplified by primer extension preamplification polymerase chain reaction, which increased the diagnostic information obtained from four to six of the seven embryos on which biopsy was performed.
CONCLUSIONS: We suggest that practical approaches for consideration within a clinical preimplantation genetic diagnosis program to limit the net effect of amplification failure (i.e., reduced embryo transfer number) include increasing the deoxyribonucleic acid content in the polymerase chain reaction tube by using more than one blastomere and by using primer extension preamplification when the initial attempt at amplification fails.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7726246     DOI: 10.1016/0002-9378(95)91468-4

Source DB:  PubMed          Journal:  Am J Obstet Gynecol        ISSN: 0002-9378            Impact factor:   8.661


  2 in total

Review 1.  Molecular diagnostics in preimplantation genetic diagnosis.

Authors:  Alan R Thornhill; Karen Snow
Journal:  J Mol Diagn       Date:  2002-02       Impact factor: 5.568

2.  Polymerase chain reaction amplification specificity: incidence of allele dropout using different DNA preparation methods for heterozygous single cells.

Authors:  S A Gitlin; S E Lanzendorf; W E Gibbons
Journal:  J Assist Reprod Genet       Date:  1996-02       Impact factor: 3.412

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.