Literature DB >> 7722904

Comparison of endothelial cell loss and phacoemulsification energy during endocapsular phacoemulsification surgery.

C Zetterström1, C G Laurell.   

Abstract

We counted central corneal endothelial cells and measured corneal thickness in 64 human eyes before and three months after cataract extraction and posterior chamber lens implantation. Cataract surgery was the same in all patients and included capsulorhexis and posterior chamber phacoemulsification of the nucleus. Total phacoemulsification energy and time were recorded. A heparin-surface-modified intraocular lens or a regular poly(methyl methacrylate) lens, both having the same design and a 5.0 mm optic, was implanted in the capsular bag with the aid of sodium hyaluronate (Healon). Mean endothelial cell loss was 4%. However, the change in cell density did not correlate with the total phacoemulsification energy used during surgery. Three months after surgery, the central corneal thickness was the same as it had been preoperatively. The results suggest that phacoemulsification in the posterior chamber is a safe procedure even in cases with a hard nucleus.

Entities:  

Mesh:

Year:  1995        PMID: 7722904     DOI: 10.1016/s0886-3350(13)80480-4

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  13 in total

1.  Long-term follow-up of changes in corneal endothelium after primary and secondary intraocular lens implantations in children.

Authors:  Mi Jeung Kim; Jeong Hun Kim; Seong-Joon Kim; Young Suk Yu
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-12-06       Impact factor: 3.117

2.  Influence of anterior chamber depth, anterior chamber volume, axial length, and lens density on postoperative endothelial cell loss.

Authors:  Anna Reuschel; Holger Bogatsch; Nicole Oertel; Renate Wiedemann
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-03-01       Impact factor: 3.117

3.  Endocapsular carousel technique phacoemulsification.

Authors:  Griffin J Jardine; Gilbert C Wong; John R Elsnab; Bruce K Gale; Balamurali K Ambati
Journal:  J Cataract Refract Surg       Date:  2011-03       Impact factor: 3.351

4.  Torsional ultrasound mode versus combined torsional and conventional ultrasound mode phacoemulsification for eyes with hard cataract.

Authors:  Mohamed A Fakhry; Malak I El Shazly
Journal:  Clin Ophthalmol       Date:  2011-07-15

5.  Safety, efficacy, and intraoperative characteristics of DisCoVisc and Healon ophthalmic viscosurgical devices for cataract surgery.

Authors:  Satish S Modi; James A Davison; Tom Walters
Journal:  Clin Ophthalmol       Date:  2011-09-23

6.  Transient corneal edema is a predictive factor for pseudophakic cystoid macular edema after uncomplicated cataract surgery.

Authors:  Jae Rock Do; Jong-Hyun Oh; Roy S Chuck; Choul Yong Park
Journal:  Korean J Ophthalmol       Date:  2015-01-22

7.  Comparative analysis of corneal morphological changes after transversal and torsional phacoemulsification through 2.2 mm corneal incision.

Authors:  Ahmed Assaf; Maged Maher Roshdy
Journal:  Clin Ophthalmol       Date:  2013-01-08

8.  Torsional ultrasound modality for hard nucleus phacoemulsification cataract extraction.

Authors:  M Zeng; X Liu; Y Liu; Y Xia; L Luo; Z Yuan; Y Zeng; Y Liu
Journal:  Br J Ophthalmol       Date:  2008-06-20       Impact factor: 4.638

9.  Evaluating the different laser fragmentation patterns used in laser cataract surgeries in terms of effective phacoemulsification time and power.

Authors:  Tukezban Huseynova; Mariko Mita; Christine Carole C Corpuz; Yuko Sotoyama; Minoru Tomita
Journal:  Clin Ophthalmol       Date:  2015-11-06

10.  Comparing the Curative Effects between Femtosecond Laser-Assisted Cataract Surgery and Conventional Phacoemulsification Surgery: A Meta-Analysis.

Authors:  Xinyi Chen; Kailin Chen; Jiliang He; Ke Yao
Journal:  PLoS One       Date:  2016-03-21       Impact factor: 3.240

View more