Literature DB >> 7703540

In vitro cytotoxicity testing of neodymium-iron-boron magnets.

V E Donohue1, F McDonald, R Evans.   

Abstract

Neodymium-iron-boron magnets are being increasingly used in orthodontic and orthopedic appliances. The purpose of this study was to investigate the in vitro cytotoxicity of these new "super" magnets. A modified agar overlay technique was performed using both L929 mouse fibroblasts and adult human oral mucosal fibroblasts. The neodyium-iron-boron magnets were tested in the following forms: uncoated magnetized, uncoated demagnetized, parylene coated demagnetized, and parylene coated magnetized. Results revealed that uncoated magnetized, uncoated demagnetized, and parylene coated magnetized were cytotoxic to both L929 mouse fibroblasts and human oral mucosal fibroblasts. However the parylene coated demagnetized neodymium magnets were only cytotoxic to the human mucosal fibroblasts. This study supports the hypothesis that these are cytotoxic effects of possibly corrosion products and of magnetism. The specific toxic effects of parylene were not examined in this present study. Statistical analysis (Mann-Whitney U-test, p = 0.014) suggested that, in this experiment, the human oral mucosal fibroblasts were more sensitive to the effects of these rare earth magnets. With the evidence of a biological effect, the use of implanted magnets must at present be limited until the safety can be assured.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7703540     DOI: 10.1002/jab.770060110

Source DB:  PubMed          Journal:  J Appl Biomater        ISSN: 1045-4861


  6 in total

1.  Testing the cytotoxicity of metal alloys used as magnetic prosthetic devices.

Authors:  M Hopp; S Rogaschewski; Th Groth
Journal:  J Mater Sci Mater Med       Date:  2003-04       Impact factor: 3.896

Review 2.  Magnetic Soft Materials and Robots.

Authors:  Yoonho Kim; Xuanhe Zhao
Journal:  Chem Rev       Date:  2022-02-01       Impact factor: 72.087

3.  Cytotoxic effect of indigenously fabricated dental magnets for application in prosthodontics.

Authors:  Satyabodh Shesharaj Guttal; Ramesh K Nadiger; Pravinkumar Shetty
Journal:  J Indian Prosthodont Soc       Date:  2018 Jan-Mar

Review 4.  The Review of Bioeffects of Static Magnetic Fields on the Oral Tissue-Derived Cells and Its Application in Regenerative Medicine.

Authors:  Wei-Zhen Lew; Sheng-Wei Feng; Sheng-Yang Lee; Haw-Ming Huang
Journal:  Cells       Date:  2021-10-05       Impact factor: 6.600

5.  Adaptive wireless millirobotic locomotion into distal vasculature.

Authors:  Tianlu Wang; Halim Ugurlu; Yingbo Yan; Mingtong Li; Meng Li; Anna-Maria Wild; Erdost Yildiz; Martina Schneider; Devin Sheehan; Wenqi Hu; Metin Sitti
Journal:  Nat Commun       Date:  2022-08-01       Impact factor: 17.694

6.  The myokinetic control interface: tracking implanted magnets as a means for prosthetic control.

Authors:  S Tarantino; F Clemente; D Barone; M Controzzi; C Cipriani
Journal:  Sci Rep       Date:  2017-12-07       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.