Literature DB >> 15348458

Testing the cytotoxicity of metal alloys used as magnetic prosthetic devices.

M Hopp1, S Rogaschewski, Th Groth.   

Abstract

Technical magnetic materials are increasingly used for the development of magnetic retained dental prosthetic and orofacial epithetic devices. Since most of the magnets based on rare earth metals, such as samarium-cobalt based alloys have a high tendency for corrosion they were first coated by tin and then encapsulated by titanium. However, the high mechanical load particularly on dental devices may cause a rupture of the titanium capsule and the alloys contact directly biological fluids. Hence, it is important to know the cytotoxicity of these magnets to assess their potential effects on the surrounding tissue. In this study, the cytotoxicity of neodymium-iron-boron and samarium-cobalt (plain, tin and titanium coated) magnets was tested. First, magnets were incubated up to 7 days in culture medium to prepare extracts for cytotoxicity measurements. Changes in the surface morphology due to corrosion were visualized by scanning electron microscopy and analysis of the elemental composition. 3T3 mouse fibroblasts were cultured in the presence of extracts and their viability measured by neutral red and metabolic assays. To learn more about a possible toxic activity of the main components of magnets, salt solutions of different concentrations resembling those elements, which are main constituents of the magnets, were used. 3T3 fibroblasts were also cultured in direct contact with the materials and material induced effects on cell morphology and growth monitored by microscopy. As a result of this study it was found that samarium-cobalt magnets have a strong tendency for corrosion and exert a considerable cytotoxicity. Neodymium-iron-boron magnets have a lesser tendency for corrosion and are only moderate cytotoxic. Coating of samarium-cobalt magnets with tin or titanium makes the materials non-toxic. Application of salt solutions shows that cobalt has a tendency to be cytotoxic at higher concentrations, but enhances cell metabolism and proliferation at lower concentrations while the other magnet constituents had a lower or negligible cytotoxic potential.

Entities:  

Year:  2003        PMID: 15348458     DOI: 10.1023/a:1022931915709

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  24 in total

1.  Distalization of maxillary first and second molars simultaneously with repelling magnets.

Authors:  L Bondemark; J Kurol
Journal:  Eur J Orthod       Date:  1992-08       Impact factor: 3.075

2.  The release of elements of dental casting alloys into cell-culture medium.

Authors:  J C Wataha; R G Craig; C T Hanks
Journal:  J Dent Res       Date:  1991-06       Impact factor: 6.116

Review 3.  Current trends in biocompatibility testing.

Authors:  C J Kirkpatrick; F Bittinger; M Wagner; H Köhler; T G van Kooten; C L Klein; M Otto
Journal:  Proc Inst Mech Eng H       Date:  1998       Impact factor: 1.617

4.  Application of a combination of neutral red and amido black staining for rapid, reliable cytotoxicity testing of biomaterials.

Authors:  G Ciapetti; D Granchi; E Verri; L Savarino; D Cavedagna; A Pizzoferrato
Journal:  Biomaterials       Date:  1996-07       Impact factor: 12.479

5.  Release of elements from some gold alloys and amalgams in corrosion.

Authors:  R Lappalainen; A Yli-Urpo
Journal:  Scand J Dent Res       Date:  1987-08

6.  Studies on the Sm-Co magnet as a dental material.

Authors:  H Tsutsui; Y Kinouchi; H Sasaki; M Shiota; T Ushita
Journal:  J Dent Res       Date:  1979-06       Impact factor: 6.116

Review 7.  High-performance permanent magnets.

Authors:  D Goll; H Kronmüller
Journal:  Naturwissenschaften       Date:  2000-10

8.  Cytotoxicity of the rare earth metals cerium, lanthanum, and neodymium in vitro: comparisons with cadmium in a pulmonary macrophage primary culture system.

Authors:  R J Palmer; J L Butenhoff; J B Stevens
Journal:  Environ Res       Date:  1987-06       Impact factor: 6.498

9.  An improved colorimetric assay for cell proliferation and viability utilizing the tetrazolium salt XTT.

Authors:  N W Roehm; G H Rodgers; S M Hatfield; A L Glasebrook
Journal:  J Immunol Methods       Date:  1991-09-13       Impact factor: 2.303

10.  The influence of nickel and cobalt on putative members of the oxygen-sensing pathway of erythropoietin-producing HepG2 cells.

Authors:  T Porwol; W Ehleben; K Zierold; J Fandrey; H Acker
Journal:  Eur J Biochem       Date:  1998-08-15
View more
  3 in total

Review 1.  Magnetic Soft Materials and Robots.

Authors:  Yoonho Kim; Xuanhe Zhao
Journal:  Chem Rev       Date:  2022-02-01       Impact factor: 72.087

2.  Cytotoxic effect of indigenously fabricated dental magnets for application in prosthodontics.

Authors:  Satyabodh Shesharaj Guttal; Ramesh K Nadiger; Pravinkumar Shetty
Journal:  J Indian Prosthodont Soc       Date:  2018 Jan-Mar

3.  Stability and in vivo safety of gold, titanium nitride and parylene C coatings on NdFeB magnets implanted in muscles towards a new generation of myokinetic prosthetic limbs.

Authors:  Veronica Iacovacci; Irene Naselli; Alice Rita Salgarella; Francesco Clemente; Leonardo Ricotti; Christian Cipriani
Journal:  RSC Adv       Date:  2021-02-08       Impact factor: 3.361

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.