Marginal fit changes during porcelain firing cycles.

D Gemalmaz1, H N Alkumru.   

Abstract

The marginal fit changes that occur during the procelain firing cycles of palladium-copper and nickel-chromium copings both with shoulder and chamfer finish lines were investigated with scanning electron microscopy. Three copings from each alloy test group were used as nonporcelainized controls. Comparisons of the firing cycles revealed a greater change during the degassing stage, and the opaque firing caused a decrease in marginal gap. There was a small increase in gap size after firing body porcelain. The marginal fit change for the palladium-copper copings (19.39 microns) during degassing was significantly greater than that for the nickel-chromium copings (8.65 microns). However, no significant differences were found when the effects of margin design and porcelain proximity to fit of metal-ceramic crowns were compared.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7699600     DOI: 10.1016/s0022-3913(05)80272-0

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  12 in total

1.  The effect of veneering on the marginal fit of CAD/CAM-generated, copy-milled, and cast metal copings.

Authors:  Sabit Melih Ates; Zeynep Yesil Duymus; Ipek Caglar; Bilal Hologlu
Journal:  Clin Oral Investig       Date:  2017-01-13       Impact factor: 3.573

2.  A comparative study of the effect of four consecutive firing cycles on the marginal fit of all: ceramic crown system and metal ceramic crown system.

Authors:  Ganesh B Bajaj
Journal:  J Indian Prosthodont Soc       Date:  2012-09-28

3.  Influence of porcelain veneering on the marginal fit of Digident and Lava CAD/CAM zirconia ceramic crowns.

Authors:  Hyun-Soon Pak; Jung-Suk Han; Jai-Bong Lee; Sung-Hun Kim; Jae-Ho Yang
Journal:  J Adv Prosthodont       Date:  2010-06-30       Impact factor: 1.904

4.  Effect of firing cycle and surface finishing on the sag resistance of long-span metal ceramic framework using base metal alloys-an in vitro study.

Authors:  Poonam Prakash; Dsj D'Souza; Manjit Kumar; M Viswambaran
Journal:  Med J Armed Forces India       Date:  2012-04-21

5.  Effect of margin design and processing steps on marginal adaptation of captek restorations.

Authors:  Amy Shih; Robert Flinton; Jayalakshmi Vaidyanathan; Tritala Vaidyanathan
Journal:  ISRN Dent       Date:  2011-06-08

6.  A comparison of marginal fit of glass infiltrated alumina copings fabricated using two different techniques and the effect of firing cycles over them.

Authors:  Hirasankar Bhowmik; Rambhao Parkhedkar
Journal:  J Adv Prosthodont       Date:  2011-12-28       Impact factor: 1.904

7.  Comparative assessment of marginal accuracy of grade II titanium and Ni-Cr alloy before and after ceramic firing: An in vitro study.

Authors:  Abhijit Patil; Kishan Singh; Sukant Sahoo; Suraj Suvarna; Prince Kumar; Anupam Singh
Journal:  Eur J Dent       Date:  2013-07

8.  Comparison of the fit accuracy of zirconia-based prostheses generated by two CAD/CAM systems.

Authors:  Seok-Joon Ha; Jin-Hyun Cho
Journal:  J Adv Prosthodont       Date:  2016-12-15       Impact factor: 1.904

9.  Comparison of the fit of cast gold crowns fabricated from the digital and the conventional impression techniques.

Authors:  Mi-Jung Yun; Young-Chan Jeon; Chang-Mo Jeong; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2017-02-07       Impact factor: 1.904

10.  Effects of metal surface grinding at the porcelain try-in stage of fixed dental prostheses.

Authors:  Halil İbrahim Kılınç; Bülent Kesim; Hasan Önder Gümüş; Mehmet Dinçel; Selçuk Erkaya
Journal:  J Adv Prosthodont       Date:  2014-08-14       Impact factor: 1.904