Literature DB >> 7696231

Detection of glaucomatous damage in patients with osteo-odontokeratoprosthesis.

G C Falcinelli1, B Falsini, M Taloni, M Piccardi, G Falcinelli.   

Abstract

BACKGROUND: Osteo-odontokeratoprosthesis (OOKP) is an autologous transplantation procedure in which the cornea is replaced by an optical cylinder glued to a biological support. Patients undergoing OOKP surgery may develop a secondary glaucoma whose diagnosis, by means of standard diagnostic procedures, is often doubtful.
METHODS: In the present study pattern electroretinograms (PERGs), visual evoked potentials (VEPs), contrast sensitivity, and automated threshold perimetry (Humphrey 30-2) were evaluated in 19 OOKP treated patients with postoperative visual acuities > or = 0.8. Nine patients had had a preoperative secondary glaucoma, while the remaining 10 had no history of glaucoma and normal posterior pole.
RESULTS: Results were compared with those obtained from either normal control subjects or from ordinary glaucoma patients. PERG amplitudes and contrast and perimetric sensitivities were reduced in both groups of OOKP patients when compared with normal controls. However, these losses were significantly greater in OOKP patients with glaucoma compared with those with normal posterior pole. VEPs were reduced, compared with controls, only in OOKP patients with glaucoma. These VEP losses were similar to those found in ordinary glaucoma patients.
CONCLUSION: Among the tests employed, VEPs showed the best accuracy (79%) in discriminating between glaucomatous and non-glaucomatous OOKP treated eyes. The present results suggest a possible use of the VEP technique for detecting glaucomatous dysfunction after OOKP.

Entities:  

Mesh:

Year:  1995        PMID: 7696231      PMCID: PMC505042          DOI: 10.1136/bjo.79.2.129

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  8 in total

1.  Strampelli's osteo-odonto-keratoprosthesis. Clinical and histological long-term features of three prostheses.

Authors:  R Ricci; I Pecorella; A Ciardi; C Della Rocca; U Di Tondo; V Marchi
Journal:  Br J Ophthalmol       Date:  1992-04       Impact factor: 4.638

2.  Pattern electroretinogram as a function of spatial frequency in ocular hypertension and early glaucoma.

Authors:  V Porciatti; B Falsini; S Brunori; A Colotto; G Moretti
Journal:  Doc Ophthalmol       Date:  1987-03       Impact factor: 2.379

3.  [Osteo-odonto keratoprosthesis].

Authors:  B Strampelli
Journal:  Ber Zusammenkunft Dtsch Ophthalmol Ges       Date:  1972

4.  The effect of corneal thickness on applanation tonometry.

Authors:  M M Whitacre; R A Stein; K Hassanein
Journal:  Am J Ophthalmol       Date:  1993-05-15       Impact factor: 5.258

5.  Quantitation of optic disc cupping.

Authors:  B E Klein; Y L Magli; K A Richie; S E Moss; S M Meuer; R Klein
Journal:  Ophthalmology       Date:  1985-12       Impact factor: 12.079

6.  Signs of early damage in glaucomatous monkey eyes: low spatial frequency losses in the pattern ERG and VEP.

Authors:  M S Marx; S M Podos; I Bodis-Wollner; P Y Lee; R F Wang; C Severin
Journal:  Exp Eye Res       Date:  1988-02       Impact factor: 3.467

7.  The pattern evoked electroretinogram in optic neuritis. A combined psychophysical and electrophysiological study.

Authors:  G T Plant; R F Hess; S J Thomas
Journal:  Brain       Date:  1986-06       Impact factor: 13.501

Review 8.  Electrophysiological and psychophysical testing of vision in glaucoma.

Authors:  I Bodis-Wollner
Journal:  Surv Ophthalmol       Date:  1989-02       Impact factor: 6.048

  8 in total
  4 in total

1.  Preliminary results after implantation of four AlphaCor artificial corneas.

Authors:  H Bleckmann; S Holak
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-08-17       Impact factor: 3.117

2.  Osteo-odonto keratoprosthesis in Stevens-Johnson syndrome: a case report.

Authors:  Reddy Sc; Tajunisah I; Tan D T
Journal:  Int J Ophthalmol       Date:  2011-04-18       Impact factor: 1.779

Review 3.  Keratoprostheses for corneal blindness: a review of contemporary devices.

Authors:  Venkata S Avadhanam; Helen E Smith; Christopher Liu
Journal:  Clin Ophthalmol       Date:  2015-04-16

4.  In vivo comparison of three different porous materials intended for use in a keratoprosthesis.

Authors:  X Y Wu; A Tsuk; H M Leibowitz; V Trinkaus-Randall
Journal:  Br J Ophthalmol       Date:  1998-05       Impact factor: 4.638

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.