Literature DB >> 7691438

Abbott AxSYM random and continuous access immunoassay system for improved workflow in the clinical laboratory.

J Smith1, G Osikowicz.   

Abstract

We describe a new clinical laboratory instrument, the Abbott AxSYM, which provides random- and continuous-access testing for immunoassays, 20 onboard reagents, primary tube sampling, and a throughput of 80 to 120 tests per hour. The AxSYM incorporates three separate analytical technologies for processing immunoassays: microparticle enzyme immunoassay, fluorescence polarization immunoassay, and a novel technology known as ion-capture immunoassay. The system incorporates both common and technology-specific subsystems controlled by a real-time software scheduling processor. Tests can be processed in one- or two-step sandwich or competitive formats, with variable pipetting steps, incubation periods, optical read formats, and wash sequences. Menu capabilities include tests for hepatitis, retrovirus, tumor markers, fertility markers, thyroid functions, and therapeutic drugs. The time to first result is approximately 15-25 min for most routine assays and < or = 15 min for stat assays (i.e., creatine kinase MB isoenzyme, human chorionic gonadotropin beta subunit, and therapeutic drugs). AxSYM assay performance for 23 assays was comparable with that of the Abbott IMx and TDx analyzers; specimen correlation data had correlation coefficients ranging from 0.97 to 0.99 and slopes ranging from 0.99 to 1.10. Within-run imprecision (CV) was 1.5% to 11.4%, with most assays (19 of 23) demonstrating CVs < or = 8.0%.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 7691438

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  5 in total

1.  Evaluation of three immunoassays used for detection of anti-rubella virus immunoglobulin M antibodies.

Authors:  Wayne Dimech; Lena Panagiotopoulos; Joan Marler; Nicolas Laven; Susan Leeson; Elizabeth M Dax
Journal:  Clin Diagn Lab Immunol       Date:  2005-09

2.  Quality of requests for serum digoxin concentrations: experience from an Australian regional health service.

Authors:  Chris Ellington; Nick Grgurinovich; John O Miners; Arduino A Mangoni
Journal:  Br J Clin Pharmacol       Date:  2006-10-30       Impact factor: 4.335

Review 3.  Prevalence of multiple micronutrient deficiencies amongst pregnant women in a rural area of Haryana.

Authors:  Priyali Pathak; Umesh Kapil; Suresh Kumar Kapoor; Renu Saxena; Anand Kumar; Nandita Gupta; Sada Nand Dwivedi; Rajvir Singh; Preeti Singh
Journal:  Indian J Pediatr       Date:  2004-11       Impact factor: 1.967

4.  Ethnicity is an independent determinant of age-specific PSA level: findings from a multiethnic Asian setting.

Authors:  Jasmine Lim; Nirmala Bhoo-Pathy; Selvalingam Sothilingam; Rohan Malek; Murali Sundram; Badrul Hisham Bahadzor; Teng Aik Ong; Keng Lim Ng; Sivaprakasam Sivalingam; Azad Hassan Abdul Razack
Journal:  PLoS One       Date:  2014-08-11       Impact factor: 3.240

5.  Health Risk, Functional Markers and Cognitive Status in Institutionalized Older Adults: A Longitudinal Study.

Authors:  Raquel Pedrero-Chamizo; Ulrike Albers; Gonzalo Palacios; Klaus Pietrzik; Agustín Meléndez; Marcela González-Gross
Journal:  Int J Environ Res Public Health       Date:  2020-10-07       Impact factor: 3.390

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.