Literature DB >> 16148178

Evaluation of three immunoassays used for detection of anti-rubella virus immunoglobulin M antibodies.

Wayne Dimech1, Lena Panagiotopoulos, Joan Marler, Nicolas Laven, Susan Leeson, Elizabeth M Dax.   

Abstract

Three automated assays (Abbott AxSYM, Bayer ADVIA Centaur, and bioMerieux VIDAS) used for the detection of rubella virus-specific immunoglobulin M were evaluated. A total of 57 samples from individuals with evidence of infection with rubella virus were used to estimate sensitivity, and 220 samples from blood donors and individuals attending an antenatal clinic who had no evidence of recent infection were used to estimate specificity. Seroconversion panels comprising an additional 31 samples from four individuals were used to determine clinical sensitivity. Samples containing potentially cross-reacting substances were also tested. The sensitivities of the three assays ranged from 84.2 to 96.5%, and the specificities ranged from 96.8 to 99.9%. The Abbott AxSYM assay detected more reactive samples than the other two assays when a panel of 57 positive samples was tested. Bayer ADVIA Centaur detected more reactive samples in the seroconversion panels than the other two assays. All three assays evaluated reported a reactive result in 1 or more of the 48 samples containing potentially cross-reacting analytes. The assays demonstrated comparable performance in testing of a well-characterized panel of samples.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16148178      PMCID: PMC1235794          DOI: 10.1128/CDLI.12.9.1104-1108.2005

Source DB:  PubMed          Journal:  Clin Diagn Lab Immunol        ISSN: 1071-412X


  28 in total

1.  Comparison of immulite with vidas for detection of infection in a low-prevalence population of pregnant women in The Netherlands.

Authors:  F Vlaspolder; P Singer; A Smit; R J Diepersloot
Journal:  Clin Diagn Lab Immunol       Date:  2001-05

2.  Antenatal screening for hepatitis B and antibodies to Toxoplasma gondii and rubella virus: evaluation of two commercial immunoassay systems.

Authors:  R J Diepersloot; H Dunnewold-Hoekstra; J Kruit-Den Hollander; F Vlaspolder
Journal:  Clin Diagn Lab Immunol       Date:  2001-07

3.  Sensitivity and specificity of viral immunoglobulin M determination by indirect enzyme-linked immunosorbent assay.

Authors:  H Champsaur; M Fattal-German; R Arranhado
Journal:  J Clin Microbiol       Date:  1988-02       Impact factor: 5.948

4.  Comparison of four enzyme immunoassays for detection of immunoglobulin M antibodies against rubella virus.

Authors:  L Matter; M Gorgievski-Hrisoho; D Germann
Journal:  J Clin Microbiol       Date:  1994-09       Impact factor: 5.948

5.  The epidemiology of rubella and congenital rubella in Australia, 1992 to 1997.

Authors:  E M Sullivan; M A Burgess; J M Forrest
Journal:  Commun Dis Intell       Date:  1999-08-05

6.  Evaluation of a new enzyme immunoassay based on recombinant Rubella virus-like particles for detection of immunoglobulin M antibodies to Rubella virus.

Authors:  L Grangeot-Keros; G Enders
Journal:  J Clin Microbiol       Date:  1997-02       Impact factor: 5.948

7.  Clinical evaluation of the sensitivity and specificity of a commercially available enzyme immunoassay for detection of rubella virus-specific immunoglobulin M.

Authors:  M A Chernesky; L Wyman; J B Mahony; S Castriciano; J T Unger; J W Safford; P S Metzel
Journal:  J Clin Microbiol       Date:  1984-09       Impact factor: 5.948

8.  PCR for detection of rubella virus RNA in clinical samples.

Authors:  T J Bosma; K M Corbett; S O'Shea; J E Banatvala; J M Best
Journal:  J Clin Microbiol       Date:  1995-05       Impact factor: 5.948

9.  Use of PCR for prenatal and postnatal diagnosis of congenital rubella.

Authors:  T J Bosma; K M Corbett; M B Eckstein; S O'Shea; P Vijayalakshmi; J E Banatvala; K Morton; J M Best
Journal:  J Clin Microbiol       Date:  1995-11       Impact factor: 5.948

10.  Rubella-specific IgM reactivity in sera from cases of infectious mononucleosis.

Authors:  P Morgan-Capner; R S Tedder; J E Mace
Journal:  J Hyg (Lond)       Date:  1983-06
View more
  2 in total

1.  Evaluation of rubella virus immunoglobulin G (IgG) and IgM assays with the new Vidia instrument.

Authors:  Maria Cristina Medici; Monica Martinelli; Valeria Albonetti; Carlo Chezzi; Giuseppe Dettori
Journal:  J Clin Microbiol       Date:  2008-03-26       Impact factor: 5.948

2.  Hospital based surveillance of congenital rubella syndrome cases in the pre-vaccine era in Amhara Regional State, Ethiopia: A base line information for the country.

Authors:  Yitayih Wondimeneh; Moges Tiruneh; Getachew Ferede; Kassahun Denekew; Fisseha Admassu; Belay Tessema
Journal:  PLoS One       Date:  2018-11-12       Impact factor: 3.240

  2 in total