Literature DB >> 7689671

Flow studies on atriopulmonary and cavopulmonary connections of the Fontan operations for congenital heart defects.

H T Low1, Y T Chew, C N Lee.   

Abstract

A comparative flow study has been conducted on two configurations of the Fontan operations for congenital heart defects in which the right ventricle is by-passed. The study was made on rigid in vitro models of the atriopulmonary and cavopulmonary connections under steady-flow conditions. It involved using pressure and flow measurements to determine the pressure-drop coefficient, pressure-energy-loss coefficient and total-energy-loss coefficient. The cavopulmonary model was found to have much lower flow losses compared to the atriopulmonary model, especially at flow rates about 5 l min-1.

Entities:  

Mesh:

Year:  1993        PMID: 7689671     DOI: 10.1016/0141-5425(93)90006-k

Source DB:  PubMed          Journal:  J Biomed Eng        ISSN: 0141-5425


  7 in total

1.  Pulmonary and caval flow dynamics after total cavopulmonary connection.

Authors:  K Houlind; E V Stenbøg; K E Sørensen; K Emmertsen; O K Hansen; L Rybro; V E Hjortdal
Journal:  Heart       Date:  1999-01       Impact factor: 5.994

2.  Wall shear stress is the primary mechanism of energy loss in the Fontan connection.

Authors:  K R Moyle; G D Mallinson; C J Occleshaw; B R Cowan; T L Gentles
Journal:  Pediatr Cardiol       Date:  2006 May-Jun       Impact factor: 1.655

Review 3.  Toward optimal hemodynamics: computer modeling of the Fontan circuit.

Authors:  E L Bove; M R de Leval; F Migliavacca; R Balossino; G Dubini
Journal:  Pediatr Cardiol       Date:  2007 Nov-Dec       Impact factor: 1.655

4.  The Advantages of Viscous Dissipation Rate over Simplified Power Loss as a Fontan Hemodynamic Metric.

Authors:  Zhenglun Alan Wei; Michael Tree; Phillip M Trusty; Wenjun Wu; Shelly Singh-Gryzbon; Ajit Yoganathan
Journal:  Ann Biomed Eng       Date:  2017-11-01       Impact factor: 3.934

Review 5.  Modeling the Fontan circulation: where we are and where we need to go.

Authors:  C G DeGroff
Journal:  Pediatr Cardiol       Date:  2007-10-05       Impact factor: 1.655

6.  Computational fluid dynamics in paediatric cardiac surgery.

Authors:  F Migliavacca; G Dubini; M de Leval
Journal:  Images Paediatr Cardiol       Date:  2000-01

7.  Using 4D Cardiovascular Magnetic Resonance Imaging to Validate Computational Fluid Dynamics: A Case Study.

Authors:  Giovanni Biglino; Daria Cosentino; Jennifer A Steeden; Lorenzo De Nova; Matteo Castelli; Hopewell Ntsinjana; Giancarlo Pennati; Andrew M Taylor; Silvia Schievano
Journal:  Front Pediatr       Date:  2015-12-14       Impact factor: 3.418

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.