Literature DB >> 7681952

ICD data storage: value in arrhythmia management.

F E Marchlinski1, C D Gottlieb, B Sarter, J Finkle, B Hook, D Callans, D Schwartzman.   

Abstract

Sophisticated diagnostic information is provided by the latest generation of implantable defibrillators. The success of therapy and the type of therapy successful in terminating ventricular arrhythmias is provided by interrogating the ICD device. In addition, R to R interval information can be retrieved. In selected devices, either local bipolar electrograms from the rate sensing leads or wide bipolar electrograms from the energy delivering leads provide visual confirmation of the presence of ventricular tachyarrthythmic events leading to therapy. The value and limitations of this sophisticated diagnostic information in providing insight into the electrical events triggering therapy and the events triggering ventricular arrhythmias are discussed.

Entities:  

Mesh:

Year:  1993        PMID: 7681952     DOI: 10.1111/j.1540-8159.1993.tb01620.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  9 in total

1.  Triggers of sustained monomorphic ventricular tachycardia differ among patients with varying etiologies of left ventricular dysfunction.

Authors:  Jonathan Rosman; Sam Hanon; Michael Shapiro; Steven J Evans; Paul Schweitzer
Journal:  Ann Noninvasive Electrocardiol       Date:  2006-04       Impact factor: 1.468

2.  Pattern of initiation of monomorphic ventricular tachycardia in recorded intracardiac electrograms.

Authors:  Majid Haghjoo; Arash Arya; Mohammad Ali Sadr-Ameli
Journal:  Indian Pacing Electrophysiol J       Date:  2005-10-01

3.  Experience with unipolar pectoral defibrillation.

Authors:  R K Reddy; G H Bardy
Journal:  Herzschrittmacherther Elektrophysiol       Date:  1997-03

4.  Implantable cardioverter defibrillator-an unusual case of inappropriate discharge during showering.

Authors:  A G Manolis; A G Katsivas; C V Vassilopoulos; N E Louvros
Journal:  J Interv Card Electrophysiol       Date:  2000-04       Impact factor: 1.900

Review 5.  Can implantable defibrillators reduce non-arrhythmic mortality?

Authors:  S Nisam
Journal:  J Interv Card Electrophysiol       Date:  1998-12       Impact factor: 1.900

6.  [Stored electrograms to differenciate between adequate and inadequate ICD therapy].

Authors:  D Müller; E Hoffman; M Fiek; A Grünewald; G Steinbeck
Journal:  Herzschrittmacherther Elektrophysiol       Date:  1997-03

7.  Volumetric left ventricular ejection fraction is superior to 2-dimensional echocardiography for risk stratification of patients for primary prevention implantable cardioverter-defibrillator implantation.

Authors:  Hussein Rayatzadeh; Shalin J Patel; Thomas H Hauser; Long L Ngo; Jaime L Shaw; Alex Tan; Alfred E Buxton; Peter Zimetbaum; Mark E Josephson; Evan Appelbaum; Warren J Manning; Reza Nezafat
Journal:  Am J Cardiol       Date:  2013-02-01       Impact factor: 2.778

8.  Identifying non-inducible ventricular tachycardia origin utilizing defibrillator electrograms.

Authors:  Cory M Tschabrunn; Elad Anter; Francis E Marchlinski
Journal:  J Interv Card Electrophysiol       Date:  2012-10-27       Impact factor: 1.900

9.  Scar heterogeneity on cardiovascular magnetic resonance as a predictor of appropriate implantable cardioverter defibrillator therapy.

Authors:  Hussein Rayatzadeh; Alex Tan; Raymond H Chan; Shalin J Patel; Thomas H Hauser; Long Ngo; Jaime L Shaw; Susie N Hong; Peter Zimetbaum; Alfred E Buxton; Mark E Josephson; Warren J Manning; Reza Nezafat
Journal:  J Cardiovasc Magn Reson       Date:  2013-04-10       Impact factor: 5.364

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.