Literature DB >> 7674890

Double-echo three-point-Dixon method for fat suppression MRI.

J Szumowski1, W Coshow, F Li, B Coombs, S F Quinn.   

Abstract

A double-echo two-excitation pulse sequence encoding fat and water signals for a phase-sensitive three-point Dixon-type analysis (DE-3PD) was developed and implemented on a 1.5 T MR imager. Data processing was performed using a previously developed two-dimensional (2D) region-growing algorithm, adapted to use double-echo data. Density-, T1-, and T2-weighted fat suppression images were obtained from six volunteers using the new fat suppression method. The images were compared with corresponding images obtained using frequency-selective excitation fat suppression (FATSAT) and a single-echo three-point-Dixon method (SE-3PD). The results demonstrate that the DE-3PD sequence shortens the imaging time by one-third compared with the SE-3PD method, without loss in image quality. The data also show that a 2D region-growing algorithm effectively unwraps the phase of DE-3PD data sets, and that results of DE-3PD fat signal suppression are consistently better than those obtained using a standard FATSAT method. The authors conclude that the double-echo sequence provides density-, T1-, and T2-weighted images that appear to be promising for routine clinical applications.

Entities:  

Mesh:

Year:  1995        PMID: 7674890     DOI: 10.1002/mrm.1910340118

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  5 in total

1.  Post-processing water-fat imaging technique for fat suppression in a low-field MR imaging system, evaluation in patients with rheumatoid arthritis.

Authors:  Kari Palosaari; Osmo Tervonen
Journal:  MAGMA       Date:  2002-11       Impact factor: 2.310

Review 2.  Liver fat content determined by magnetic resonance imaging and spectroscopy.

Authors:  Fabian Springer; Jürgen Machann; Claus D Claussen; Fritz Schick; Nina F Schwenzer
Journal:  World J Gastroenterol       Date:  2010-04-07       Impact factor: 5.742

3.  Three-point Dixon method with a MISSTEC sequence.

Authors:  F Lethimonnier; F Franconi; S Akoka
Journal:  MAGMA       Date:  1997-12       Impact factor: 2.310

4.  CEST-FISP: a novel technique for rapid chemical exchange saturation transfer MRI at 7 T.

Authors:  T Shah; L Lu; K M Dell; M D Pagel; M A Griswold; C A Flask
Journal:  Magn Reson Med       Date:  2010-10-11       Impact factor: 4.668

5.  Non-Invasive Electrical Impedance Tomography for Multi-Scale Detection of Liver Fat Content.

Authors:  Yuan Luo; Parinaz Abiri; Shell Zhang; Chih-Chiang Chang; Amir H Kaboodrangi; Rongsong Li; Ashish K Sahib; Alex Bui; Rajesh Kumar; Mary Woo; Zhaoping Li; René R Sevag Packard; Yu-Chong Tai; Tzung K Hsiai
Journal:  Theranostics       Date:  2018-02-08       Impact factor: 11.556

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.