Literature DB >> 7672853

Mechanical evaluation of craniofacial osseointegration retention systems.

V Del Valle1, G Faulkner, J Wolfaardt, B Rangert, H K Tan.   

Abstract

This study evaluates mechanical behavior of retention systems that have been used in craniofacial osseointegration. A loading/measuring apparatus was custom designed and constructed. Test bases that represented a typical auricular situation were constructed. These bases allowed for three points of retention. Jigs that could be reproducibly positioned carried the reciprocal portion of the retentive components. The test apparatus provided vertical and horizontal loads in five locations. The system was used to test two ball-and-socket attachments (Dalla Bona; Nobelpharma), cast and preformed bar and clips (Nobelpharma), and three magnet systems (Dynamag; Neomag; Technovent). The loading/measuring apparatus was also used to evaluate the performance of two facial prosthetic adhesives. Retention systems employed in craniofacial osseointegration offer more predictable retention than the facial prosthetic adhesives. The mechanical retention systems are best suited to situations where tensile and shear forces will operate. Magnet systems are best used where only tensile forces are anticipated or where horizontal forces on the implants are to be avoided.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7672853

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  6 in total

1.  Selective serotonin reuptake inhibitors and the risk of osseointegrated implant failure: a cohort study.

Authors:  X Wu; K Al-Abedalla; E Rastikerdar; S Abi Nader; N G Daniel; B Nicolau; F Tamimi
Journal:  J Dent Res       Date:  2014-09-03       Impact factor: 6.116

2.  Lobe of sound: prosthetic rehabilitation of partial auriculectomy defect.

Authors:  Ashmi Sebastian; Sanjayagouda B Patil; Anantha N Sundararajan; Lakkappa S Ganiger
Journal:  BMJ Case Rep       Date:  2020-09-09

3.  A different wax sculpture technique for implant-retained auricular prosthesis.

Authors:  Necla Demir; Pınar Cevik; Yener Okutan; A Nilgun Ozturk; Bahar Colpan
Journal:  Eur J Dent       Date:  2015 Jul-Sep

4.  Rehabilitation of a missing ear with an implant retained auricular prosthesis.

Authors:  Satyabodh Sheshraj Guttal; Shruti Shanbhag; Sudhindra S Kulkarni; Srinath L Thakur
Journal:  J Indian Prosthodont Soc       Date:  2015 Jan-Mar

5.  Rehabilitation of Unilateral Congenital Microtia by Implant-retained Prosthesis.

Authors:  Abhay Datarkar; Surendra Daware; Ravi Dande; Ujwala Datarkar
Journal:  Ann Maxillofac Surg       Date:  2017 Jul-Dec

6.  Implant-retained auricular prosthesis: a case report.

Authors:  A Nilgun Ozturk; Aslihan Usumez; Zekeriya Tosun
Journal:  Eur J Dent       Date:  2010-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.