| Literature DB >> 7671764 |
M H Seelig1, R Kasperk, L Tietze, V Schumpelick.
Abstract
Erosions of intraabdominal hollow viscus are possible complications following reconstructive surgery of the abdominal wall after hernia repair with non-absorbable biomaterials. A rare case of manifestation of a enterocutaneous fistula by chronical erosion of a Marlex mesh after repair of an incisional hernia is presented. Successful treatment was achieved by fistulectomy, small bowel segmental resection and limited resection of the implanted Marlex mesh.Entities:
Mesh:
Substances:
Year: 1995 PMID: 7671764