Literature DB >> 7668392

Performance comparison of several published tissue near-infrared spectroscopy algorithms.

S J Matcher1, C E Elwell, C E Cooper, M Cope, D T Delpy.   

Abstract

We have collected multiwavelength near-infrared (NIR) attenuation spectra on human forearm muscle, the adult rat head, and newborn piglet head to compare the changes in chromophore concentration derived from these data using published algorithms from four groups. We find differences between the results from the algorithms on each data set, particularly in their estimation of cytochrome oxidase (cyt-aa3) redox changes. We also find some differences when applying the same algorithm to the three data sets, suggesting possible difficulties in transferring algorithms between different physiological systems (e.g., Kurth, C. D., Steven, J. M., Benaron, D., and Chance, B. (1993) J. Clin. Monit. 9, 163-170). We have also compared the algorithms using simulated data generated using measured hemoglobin absorption spectra and a diffusion model for light transport in tissue. We find that while the algorithms from three groups are in broad agreement, that published by Piantadosi (Piantadosi, C. A. (1993) Methods Toxicol. 2, 107-126) produces significantly different results for cyt-aa3 and HbO2. Either the hemoglobin spectra used to produce the simulated data are inaccurate or the modeling is incorrect, or this algorithm is erroneous.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7668392     DOI: 10.1006/abio.1995.1252

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  113 in total

1.  A new broadband near-infrared spectroscopy system for in-vivo measurements of cerebral cytochrome-c-oxidase changes in neonatal brain injury.

Authors:  Gemma Bale; Subhabrata Mitra; Judith Meek; Nicola Robertson; Ilias Tachtsidis
Journal:  Biomed Opt Express       Date:  2014-09-05       Impact factor: 3.732

2.  Reduction of collateral thermal impact of diode laser irradiation on soft tissue due to modified application parameters.

Authors:  F Beer; W Körpert; H Passow; A Steidler; A Meinl; A G Buchmair; A Moritz
Journal:  Lasers Med Sci       Date:  2011-10-28       Impact factor: 3.161

3.  Spatial frequency domain spectroscopy of two layer media.

Authors:  Dmitry Yudovsky; Anthony J Durkin
Journal:  J Biomed Opt       Date:  2011-10       Impact factor: 3.170

4.  A wireless handheld probe with spectrally constrained evolution strategies for diffuse optical imaging of tissue.

Authors:  M L Flexman; H K Kim; R Stoll; M A Khalil; C J Fong; A H Hielscher
Journal:  Rev Sci Instrum       Date:  2012-03       Impact factor: 1.523

Review 5.  Haemoglobin oxygen saturation as a biomarker: the problem and a solution.

Authors:  David A Boas; Maria Angela Franceschini
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2011-11-28       Impact factor: 4.226

6.  Removal of motion artifacts originating from optode fluctuations during functional near-infrared spectroscopy measurements.

Authors:  Toru Yamada; Shinji Umeyama; Mitsuo Ohashi
Journal:  Biomed Opt Express       Date:  2015-11-02       Impact factor: 3.732

7.  Separation of the global and local components in functional near-infrared spectroscopy signals using principal component spatial filtering.

Authors:  Xian Zhang; Jack Adam Noah; Joy Hirsch
Journal:  Neurophotonics       Date:  2016-02-05       Impact factor: 3.593

Review 8.  Cerebral and tissue oximetry.

Authors:  Jochen Steppan; Charles W Hogue
Journal:  Best Pract Res Clin Anaesthesiol       Date:  2014-09-28

9.  Dynamic model for the tissue concentration and oxygen saturation of hemoglobin in relation to blood volume, flow velocity, and oxygen consumption: Implications for functional neuroimaging and coherent hemodynamics spectroscopy (CHS).

Authors:  Sergio Fantini
Journal:  Neuroimage       Date:  2013-04-10       Impact factor: 6.556

10.  MAESTROS: A Multiwavelength Time-Domain NIRS System to Monitor Changes in Oxygenation and Oxidation State of Cytochrome-C-Oxidase.

Authors:  Frederic Lange; Luke Dunne; Lucy Hale; Ilias Tachtsidis
Journal:  IEEE J Sel Top Quantum Electron       Date:  2018-05-09       Impact factor: 4.544

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.